Anker SOLIX official logoCEC-Listed · ResidentialUL 9540 (Ed. 3 : 2023)LFP (LiFePO4)

Anker SOLIX A17E1-2 (12.29 kWh)

7.68 kW, 12.288 kWh, 240 Vac energy storage system. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Usable Energy
12.29 kWh
Continuous Output
8 kW
Round-Trip Eff.
90%Class Estimate
1.5 kW Outage Runtime
7.8 hrs
Backup & Kit Actions
Compare vs Standby Generator →
Anker SOLIX A17E1-2 — Illustrative category photo — not this exact model (residential battery & home backup system)
Illustrative category photo — not this exact model (residential battery & home backup system)The Solar House Project Editorial Archive
SINGLE-UNIT OUTAGE RUNTIME (12.29 kWh · 8 kW · LFP (LIFEPO4)) Light Load (0.8 kW) 12.4 hrsEssentials (1.5 kW) 6.6 hrsWhole-Home + HVAC (4.5 kW) 2.2 hrs

Storage Specifications & Safety Listing

Anker SOLIX A17E1-2 Technical Specifications
ManufacturerAnker SOLIX
Model Number (MPN)A17E1-2
Battery ChemistryLFP (LiFePO4)
Usable Energy Capacity12.29 kWh
Max Continuous Discharge8 kW
Round-Trip Efficiency (RTE)90% (Class Estimate — Not listed in CEC)
PV DC Input (DC-Coupled)Yes (DC-Coupled Capable)
Nominal AC Grid Voltage240 Vac
Safety ListingUL 9540 (Ed. 3 : 2023)
Certifying LaboratorySGS

Single-Unit Blackout Runtime Estimates

Modeled as usable kWh × √(RTE) ÷ load kW (12.29 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.

Single-Unit Outage Runtime Estimates for A17E1-2
Light Essentials (0.8 kW — fridge, Wi-Fi, lights)14.6 hrs
Standard Backup (1.5 kW — + sump/freezer/home office)7.8 hrs
Heavy Load / HVAC (4.5 kW continuous)2.6 hrs

Multi-Unit Stacking Matrix

Multi-Unit Battery Stacking Runtime Matrix for A17E1-2
UnitsTotal kWhCont. kW1.5 kW Backup4.5 kW HVAC
1×12.3 kWh8.0 kW7.8 hrs2.6 hrs
2×24.6 kWh16.0 kW15.5 hrs5.2 hrs
3×36.9 kWh24.0 kW23.3 hrs7.8 hrs
4×49.2 kWh32.0 kW31.1 hrs10.4 hrs

Outage Sizing Notes & FAQ — Anker SOLIX A17E1-2

When sizing a residential storage bank around the Anker SOLIX A17E1-2 (12.29 kWh usable, 8 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 7.8 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.

How long will one Anker SOLIX A17E1-2 run during a power outage?
Using one-way discharge efficiency (√90% ≈ 94.9%) on 12.29 kWh usable capacity without solar recharge, one A17E1-2 delivers approximately 14.6 hours at a 0.8 kW light-essentials load (fridge, Wi-Fi, LED lights) or 7.8 hours at a 1.5 kW standard backup load.
Can the Anker SOLIX A17E1-2 run a central air conditioner or heat pump?
A single unit supplies 8 kW continuous AC power, enough to sustain a 4.5 kW HVAC load for roughly 2.6 hours on battery alone. Always verify Locked Rotor Amps (LRA) compressor startup surge and install a soft-start kit if your condenser LRA exceeds inverter peak surge rating.
Is the Anker SOLIX A17E1-2 AC-coupled or DC-coupled, and what safety listing does it hold?
In the CEC registry (snapshot 2026-11-23), this LFP (LiFePO4) battery carries UL 9540 (Ed. 3 : 2023) certification (tested by SGS) and is listed as DC-coupled capable with direct PV DC input. Confirm UL 9540 / UL 9540A spacing rules with your local AHJ.

More Anker SOLIX Energy Storage Models

X1-P6K-B05-US (5 kWh)A17E1-1 (6.14 kWh)X1-P6K-B10-US (10 kWh)X1-P6K-B15-US (15 kWh)A17E1-3 (18.43 kWh)X1-P6K-B20-US (20 kWh)All Anker SOLIX Equipment →