Running Watts · LRA Surge Audit · 10-Year TCO

Blackout & Backup Power Configurator: Generator vs. Battery

Check off the circuits you need during a grid outage, test the impact of an AC soft-start kit, and compare installed plus 10-year ownership costs for standby gas generators vs. LFP home batteries.

Resolved to Texas. Gas $1.54/therm · Electricity 15.2¢/kWh · 5.5 peak sun hours

Battery leans ahead
Running Load
1.0 kW
1,320 W nameplate × 0.72 diversity
Peak Surge
2.4 kW
Running + Gas Furnace Blower start
Daily Energy Need
11.6 kWh
per day at the duty cycles shown
Outage Energy
12 kWh
1 day
Standby Generator
14 kW
Natural gas / propane + 200A ATS
LFP Battery
1 unit
13.5 kWh · 11.5 kW continuous
LFP battery has the lower 10-year cost here

$10,091 over 10 years versus $13,903 for a 14 kW standby generator.

Load vs. Surge Gauge

Running 1.0 kWStartup surge +1.4 kW
14 kW generator051015201 × 11.5 = 11.5 kW battery

Solid line: 14 kW generator rating. Dashed line: continuous output of 1 unit. Surge is the diversified running load plus the largest single motor start.

Standby Generator200A ATS included

14 kW · Natural Gas / Propane

Steady load
1.0 kW of 14 kW (7% loaded)
Inrush
2.4 kW fits within the rating
Runtime
Unlimited on a gas meter · about 32 days on a 500-gal propane tank
Fuel per outage
11 therms ≈ $18 at TX gas rates
  • Runs the whole house for days regardless of weather
  • Refuels from the utility — no delivery logistics on natural gas
  • Needs annual service, exercise cycles, and an outdoor pad
10-Year Cost
$13,903
LFP Battery Wall11.5 kW / 185A LRA per unit

1 × 13.5 kWh

Usable energy
13 kWh of 13.5 kWh nameplate
Power
11.5 kW continuous · 185A motor start for a 2.4 kW peak
Runtime
About 1 day at this load with no recharge until the grid returns
Sized by
Energy needs 1, power 1, motor start 1
  • Silent, no exhaust, serviceable indoors or in a garage
  • Recharges from rooftop solar and earns self-consumption value
  • Finite energy — past about 6 units most residential gateways need to be multiplied
10-Year Cost
$10,091

10-Year Cost of Ownership

Cost Line14 kW Generator1 unit Battery
Equipment$4,700$7,400
Installation labor, pad, gas line, permit$3,452$1,168
200A ATS / backup gateway$1,675$1,523
Maintenance over 10 years$3,900$0
Outage fuel over 10 years$175$0
Solar self-consumption offset over 10 years——
10-year total$13,903$10,091
How these cost estimates work

US mid-range 2026 prices scaled by a state labor index derived from the 200A panel benchmark (1.02× in Texas). Fuel assumes one outage of 1 day every year for 10 years at $1.54/therm. No solar self-consumption credit is applied; switch on “Paired with Rooftop Solar” to include it. Figures are planning estimates, not quotes — have a licensed installer confirm sizes against the nameplate LRA of your actual equipment.

Compare standby generators and solar batteries →

Why LRA Startup Surge Breaks Undersized Backup Systems

Most homeowners add up running watts on appliance stickers and forget Locked Rotor Amps (LRA) — the 0.3-second electrical spike when a central AC compressor or 240V submersible well pump starts. Adding a $350 soft-start kit to a 3–4 ton central AC drops starting surge by up to 70%, saving thousands on generator or inverter sizing.