Anker SOLIX X1-P6K-B25-US (25 kWh)
6 kW, 25 kWh, 240 Vac lithium iron phosphate energy storage system with PCS functionality. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Storage Specifications & Safety Listing
| Manufacturer | Anker SOLIX |
|---|---|
| Model Number (MPN) | X1-P6K-B25-US |
| Battery Chemistry | LFP (LiFePO4) |
| Usable Energy Capacity | 25 kWh |
| Max Continuous Discharge | 6 kW |
| Round-Trip Efficiency (RTE) | 90% (Class Estimate — Not listed in CEC) |
| PV DC Input (DC-Coupled) | AC-Coupled / External Hybrid Inverter |
| Nominal AC Grid Voltage | 240 Vac |
| Safety Listing | UL 9540 (Ed. 2 : 2020) |
| Certifying Laboratory | CSA Group |
Single-Unit Blackout Runtime Estimates
Modeled as usable kWh × √(RTE) ÷ load kW (25 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.
| Light Essentials (0.8 kW — fridge, Wi-Fi, lights) | 29.6 hrs |
|---|---|
| Standard Backup (1.5 kW — + sump/freezer/home office) | 15.8 hrs |
| Heavy Load / HVAC (4.5 kW continuous) | 5.3 hrs |
Multi-Unit Stacking Matrix
| Units | Total kWh | Cont. kW | 1.5 kW Backup | 4.5 kW HVAC |
|---|---|---|---|---|
| 1× | 25.0 kWh | 6.0 kW | 15.8 hrs | 5.3 hrs |
| 2× | 50.0 kWh | 12.0 kW | 31.6 hrs | 10.5 hrs |
| 3× | 75.0 kWh | 18.0 kW | 47.4 hrs | 15.8 hrs |
| 4× | 100.0 kWh | 24.0 kW | 63.2 hrs | 21.1 hrs |
Outage Sizing Notes & FAQ — Anker SOLIX X1-P6K-B25-US
When sizing a residential storage bank around the Anker SOLIX X1-P6K-B25-US (25 kWh usable, 6 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 15.8 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.