Deye official logoGlobal / Non-US ReferenceUL 9540 (Ed. 3 : 2023)LFP (LiFePO4)

Deye BOS-A50 (53.76 kWh)

43 kW, 53.76 kWh, energy storage system. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Usable Energy
53.76 kWh
Continuous Output
43 kW
Round-Trip Eff.
90%Class Estimate
1.5 kW Outage Runtime
34 hrs
Backup & Kit Actions
Global / Non-US Reference: View CEC-listed US UL 9540 / UL 1973 residential equivalents below for US solar + backup installations.
View US Equivalents →Compare vs Standby Generator →
Deye BOS-A50 — Illustrative category photo — not this exact model (residential battery & home backup system)
Illustrative category photo — not this exact model (residential battery & home backup system)The Solar House Project Editorial Archive
SINGLE-UNIT OUTAGE RUNTIME (53.76 kWh · 43 kW · LFP (LIFEPO4)) Light Load (0.8 kW) 54.4 hrsEssentials (1.5 kW) 29 hrsWhole-Home + HVAC (4.5 kW) 9.7 hrs

Storage Specifications & Safety Listing

Deye BOS-A50 Technical Specifications
ManufacturerDeye
Model Number (MPN)BOS-A50
Battery ChemistryLFP (LiFePO4)
Usable Energy Capacity53.76 kWh
Max Continuous Discharge43 kW
Round-Trip Efficiency (RTE)90% (Class Estimate — Not listed in CEC)
PV DC Input (DC-Coupled)AC-Coupled / External Hybrid Inverter
Nominal AC Grid Voltage240 Vac
Safety ListingUL 9540 (Ed. 3 : 2023)
Certifying LaboratoryTUV Rheinland of North America

Single-Unit Blackout Runtime Estimates

Modeled as usable kWh × √(RTE) ÷ load kW (53.76 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.

Single-Unit Outage Runtime Estimates for BOS-A50
Light Essentials (0.8 kW — fridge, Wi-Fi, lights)63.8 hrs
Standard Backup (1.5 kW — + sump/freezer/home office)34 hrs
Heavy Load / HVAC (4.5 kW continuous)11.3 hrs

Multi-Unit Stacking Matrix

Multi-Unit Battery Stacking Runtime Matrix for BOS-A50
UnitsTotal kWhCont. kW1.5 kW Backup4.5 kW HVAC
1×53.8 kWh43.0 kW34.0 hrs11.3 hrs
2×107.5 kWh86.0 kW68.0 hrs22.7 hrs
3×161.3 kWh129.0 kW102.0 hrs34.0 hrs
4×215.0 kWh172.0 kW136.0 hrs45.3 hrs

Outage Sizing Notes & FAQ — Deye BOS-A50

When sizing a residential storage bank around the Deye BOS-A50 (53.76 kWh usable, 43 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 34 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.

How long will one Deye BOS-A50 run during a power outage?
Using one-way discharge efficiency (√90% ≈ 94.9%) on 53.76 kWh usable capacity without solar recharge, one BOS-A50 delivers approximately 63.8 hours at a 0.8 kW light-essentials load (fridge, Wi-Fi, LED lights) or 34 hours at a 1.5 kW standard backup load.
Can the Deye BOS-A50 run a central air conditioner or heat pump?
A single unit supplies 43 kW continuous AC power, enough to sustain a 4.5 kW HVAC load for roughly 11.3 hours on battery alone. Always verify Locked Rotor Amps (LRA) compressor startup surge and install a soft-start kit if your condenser LRA exceeds inverter peak surge rating.
Is the Deye BOS-A50 AC-coupled or DC-coupled, and what safety listing does it hold?
In the CEC registry (snapshot 2026-11-23), this LFP (LiFePO4) battery carries UL 9540 (Ed. 3 : 2023) certification (tested by TUV Rheinland of North America) and is listed as AC-coupled / paired via an external hybrid inverter. Confirm UL 9540 / UL 9540A spacing rules with your local AHJ.

CEC-Listed UL 9540 / UL 1973 Equivalents

CEC-Listed · Residential35.84 kWh
Pylontech · UL 9540 (Ed. 3 : 2023)

Force-H3-102.4/716.8-US

Continuous Output: 35.84 kW
Datasheet →
CEC-Listed · Residential40.19 kWh
Zhongrui Green Energy Technology (Shenzhen) · UL 9540 (Ed. 3 : 2023)

ZR-XS05A1502US

Continuous Output: 15 kW
Datasheet →
CEC-Listed · Residential40 kWh
Eternalplanet Energy · UL 9540 (Ed. 3 : 2023)

EP Cube2 UL-S-40G

Continuous Output: 11.5 kW
Datasheet →

More Deye Energy Storage Models

SE-G10-15K-US (51.2 kWh)SE-G10-5K-US (51.2 kWh)SE-G10-8K-US (51.2 kWh)BOS-G55-S60-C1-US (56.32 kWh)BOS-GH55-S60-C1-US (56.32 kWh)SE-G11-12K-US (56.32 kWh)All Deye Equipment →