EG4 Electronics WM-48-314-1-IN-XX (16 kWh)
10.2 kW, 16 kWh, battery energy storage system, where XX may be 00-99. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Storage Specifications & Safety Listing
| Manufacturer | EG4 Electronics |
|---|---|
| Model Number (MPN) | WM-48-314-1-IN-XX |
| Battery Chemistry | LFP (LiFePO4) |
| Usable Energy Capacity | 16 kWh |
| Max Continuous Discharge | 10.2 kW |
| Round-Trip Efficiency (RTE) | 90% (Class Estimate — Not listed in CEC) |
| PV DC Input (DC-Coupled) | AC-Coupled / External Hybrid Inverter |
| Nominal AC Grid Voltage | 240 Vac |
| Safety Listing | UL 9540 (Ed. 3 : 2023) |
| Certifying Laboratory | Intertek |
Single-Unit Blackout Runtime Estimates
Modeled as usable kWh × √(RTE) ÷ load kW (16 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.
| Light Essentials (0.8 kW — fridge, Wi-Fi, lights) | 19 hrs |
|---|---|
| Standard Backup (1.5 kW — + sump/freezer/home office) | 10.1 hrs |
| Heavy Load / HVAC (4.5 kW continuous) | 3.4 hrs |
Multi-Unit Stacking Matrix
| Units | Total kWh | Cont. kW | 1.5 kW Backup | 4.5 kW HVAC |
|---|---|---|---|---|
| 1× | 16.0 kWh | 10.2 kW | 10.1 hrs | 3.4 hrs |
| 2× | 32.0 kWh | 20.4 kW | 20.2 hrs | 6.7 hrs |
| 3× | 48.0 kWh | 30.6 kW | 30.4 hrs | 10.1 hrs |
| 4× | 64.0 kWh | 40.8 kW | 40.5 hrs | 13.5 hrs |
Outage Sizing Notes & FAQ — EG4 Electronics WM-48-314-1-IN-XX
When sizing a residential storage bank around the EG4 Electronics WM-48-314-1-IN-XX (16 kWh usable, 10.2 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 10.1 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.