GoodWe official logoCEC-Listed · ResidentialUL 9540 (Ed. 1 : 2016)NMC / Lithium-Ion

GoodWe A-BP6000 (9.6 kWh)

6 kW, 9.6 kWh, 240 Vac lithium ion energy storage system. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Usable Energy
9.6 kWh
Continuous Output
5 kW
Round-Trip Eff.
90%Class Estimate
1.5 kW Outage Runtime
6.1 hrs
Backup & Kit Actions
Compare vs Standby Generator →
GoodWe A-BP6000 — Illustrative category photo — not this exact model (residential battery & home backup system)
Illustrative category photo — not this exact model (residential battery & home backup system)The Solar House Project Editorial Archive
SINGLE-UNIT OUTAGE RUNTIME (9.6 kWh · 5 kW · NMC / LITHIUM-ION) Light Load (0.8 kW) 9.7 hrsEssentials (1.5 kW) 5.2 hrsWhole-Home + HVAC (4.5 kW) 1.7 hrs

Storage Specifications & Safety Listing

GoodWe A-BP6000 Technical Specifications
ManufacturerGoodWe
Model Number (MPN)A-BP6000
Battery ChemistryNMC / Lithium-Ion
Usable Energy Capacity9.6 kWh
Max Continuous Discharge5 kW
Round-Trip Efficiency (RTE)90% (Class Estimate — Not listed in CEC)
PV DC Input (DC-Coupled)AC-Coupled / External Hybrid Inverter
Nominal AC Grid Voltage240 Vac
Safety ListingUL 9540 (Ed. 1 : 2016)
Certifying LaboratorySGS

Single-Unit Blackout Runtime Estimates

Modeled as usable kWh × √(RTE) ÷ load kW (9.6 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.

Single-Unit Outage Runtime Estimates for A-BP6000
Light Essentials (0.8 kW — fridge, Wi-Fi, lights)11.4 hrs
Standard Backup (1.5 kW — + sump/freezer/home office)6.1 hrs
Heavy Load / HVAC (4.5 kW continuous)2 hrs

Multi-Unit Stacking Matrix

Multi-Unit Battery Stacking Runtime Matrix for A-BP6000
UnitsTotal kWhCont. kW1.5 kW Backup4.5 kW HVAC
1×9.6 kWh5.0 kW6.1 hrs2.0 hrs
2×19.2 kWh10.0 kW12.1 hrs4.0 hrs
3×28.8 kWh15.0 kW18.2 hrs6.1 hrs
4×38.4 kWh20.0 kW24.3 hrs8.1 hrs

Outage Sizing Notes & FAQ — GoodWe A-BP6000

When sizing a residential storage bank around the GoodWe A-BP6000 (9.6 kWh usable, 5 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 6.1 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.

How long will one GoodWe A-BP6000 run during a power outage?
Using one-way discharge efficiency (√90% ≈ 94.9%) on 9.6 kWh usable capacity without solar recharge, one A-BP6000 delivers approximately 11.4 hours at a 0.8 kW light-essentials load (fridge, Wi-Fi, LED lights) or 6.1 hours at a 1.5 kW standard backup load.
Can the GoodWe A-BP6000 run a central air conditioner or heat pump?
A single unit supplies 5 kW continuous AC power, enough to sustain a 4.5 kW HVAC load for roughly 2 hours on battery alone. Always verify Locked Rotor Amps (LRA) compressor startup surge and install a soft-start kit if your condenser LRA exceeds inverter peak surge rating.
Is the GoodWe A-BP6000 AC-coupled or DC-coupled, and what safety listing does it hold?
In the CEC registry (snapshot 2026-11-23), this NMC / Lithium-Ion battery carries UL 9540 (Ed. 1 : 2016) certification (tested by SGS) and is listed as AC-coupled / paired via an external hybrid inverter. Confirm UL 9540 / UL 9540A spacing rules with your local AHJ.

More GoodWe Energy Storage Models

A-BF5000 (9.6 kWh)A-BF6000 (9.6 kWh)A-BF7000 (9.6 kWh)All GoodWe Equipment →