JinkoSolar official logoCEC-Listed · ResidentialUL 9540 (Ed. 2 : 2020)LFP (LiFePO4)

JinkoSolar JKS-R-7S31-US19.20-1P (19.2 kWh)

7.6 kW, 19.2 kWh 240 VAC, LFP Energy Storage System. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Usable Energy
19.2 kWh
Continuous Output
7.6 kW
Round-Trip Eff.
89%
1.5 kW Outage Runtime
12.1 hrs
Backup & Kit Actions
Compare vs Standby Generator →
JinkoSolar JKS-R-7S31-US19.20-1P — Illustrative category photo — not this exact model (residential battery & home backup system)
Illustrative category photo — not this exact model (residential battery & home backup system)The Solar House Project Editorial Archive
SINGLE-UNIT OUTAGE RUNTIME (19.2 kWh · 7.6 kW · LFP (LIFEPO4)) Light Load (0.8 kW) 19.2 hrsEssentials (1.5 kW) 10.3 hrsWhole-Home + HVAC (4.5 kW) 3.4 hrs

Storage Specifications & Safety Listing

JinkoSolar JKS-R-7S31-US19.20-1P Technical Specifications
ManufacturerJinkoSolar
Model Number (MPN)JKS-R-7S31-US19.20-1P
Battery ChemistryLFP (LiFePO4)
Usable Energy Capacity19.2 kWh
Max Continuous Discharge7.6 kW
Round-Trip Efficiency (RTE)89%
PV DC Input (DC-Coupled)Yes (DC-Coupled Capable)
Nominal AC Grid Voltage240 Vac
Safety ListingUL 9540 (Ed. 2 : 2020)
Certifying LaboratoryCSA Group

Single-Unit Blackout Runtime Estimates

Modeled as usable kWh × √(RTE) ÷ load kW (19.2 kWh × 94.3% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.

Single-Unit Outage Runtime Estimates for JKS-R-7S31-US19.20-1P
Light Essentials (0.8 kW — fridge, Wi-Fi, lights)22.6 hrs
Standard Backup (1.5 kW — + sump/freezer/home office)12.1 hrs
Heavy Load / HVAC (4.5 kW continuous)4 hrs

Multi-Unit Stacking Matrix

Multi-Unit Battery Stacking Runtime Matrix for JKS-R-7S31-US19.20-1P
UnitsTotal kWhCont. kW1.5 kW Backup4.5 kW HVAC
1×19.2 kWh7.6 kW12.1 hrs4.0 hrs
2×38.4 kWh15.2 kW24.2 hrs8.1 hrs
3×57.6 kWh22.8 kW36.2 hrs12.1 hrs
4×76.8 kWh30.4 kW48.3 hrs16.1 hrs

Outage Sizing Notes & FAQ — JinkoSolar JKS-R-7S31-US19.20-1P

When sizing a residential storage bank around the JinkoSolar JKS-R-7S31-US19.20-1P (19.2 kWh usable, 7.6 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 12.1 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.

How long will one JinkoSolar JKS-R-7S31-US19.20-1P run during a power outage?
Using one-way discharge efficiency (√89% ≈ 94.3%) on 19.2 kWh usable capacity without solar recharge, one JKS-R-7S31-US19.20-1P delivers approximately 22.6 hours at a 0.8 kW light-essentials load (fridge, Wi-Fi, LED lights) or 12.1 hours at a 1.5 kW standard backup load.
Can the JinkoSolar JKS-R-7S31-US19.20-1P run a central air conditioner or heat pump?
A single unit supplies 7.6 kW continuous AC power, enough to sustain a 4.5 kW HVAC load for roughly 4 hours on battery alone. Always verify Locked Rotor Amps (LRA) compressor startup surge and install a soft-start kit if your condenser LRA exceeds inverter peak surge rating.
Is the JinkoSolar JKS-R-7S31-US19.20-1P AC-coupled or DC-coupled, and what safety listing does it hold?
In the CEC registry (snapshot 2026-11-23), this LFP (LiFePO4) battery carries UL 9540 (Ed. 2 : 2020) certification (tested by CSA Group) and is listed as DC-coupled capable with direct PV DC input. Confirm UL 9540 / UL 9540A spacing rules with your local AHJ.

More JinkoSolar Energy Storage Models

JKS-R-7S21-US2620 (26.2 kWh)All JinkoSolar Equipment →