KC CEC-Listed · ResidentialUL 9540 (Ed. 1 : 2016)LFP (LiFePO4)

Kohler Co 350-10LC (10 kWh)

7.6 kW, 10 kWh, LFP Energy Storage System. Only capable of receiving DC input from PV module system if equipped with a hybrid inverter component. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Usable Energy
10 kWh
Continuous Output
7.6 kW
Round-Trip Eff.
96.1%
1.5 kW Outage Runtime
6.5 hrs
Backup & Kit Actions
Compare vs Standby Generator →
Kohler Co 350-10LC — Illustrative category photo — not this exact model (residential battery & home backup system)
Illustrative category photo — not this exact model (residential battery & home backup system)The Solar House Project Editorial Archive
SINGLE-UNIT OUTAGE RUNTIME (10 kWh · 7.6 kW · LFP (LIFEPO4)) Light Load (0.8 kW) 10.8 hrsEssentials (1.5 kW) 5.8 hrsWhole-Home + HVAC (4.5 kW) 1.9 hrs

Storage Specifications & Safety Listing

Kohler Co 350-10LC Technical Specifications
ManufacturerKohler Co
Model Number (MPN)350-10LC
Battery ChemistryLFP (LiFePO4)
Usable Energy Capacity10 kWh
Max Continuous Discharge7.6 kW
Round-Trip Efficiency (RTE)96.1%
PV DC Input (DC-Coupled)AC-Coupled / External Hybrid Inverter
Nominal AC Grid Voltage240 Vac
Safety ListingUL 9540 (Ed. 1 : 2016)
Certifying LaboratoryIntertek

Single-Unit Blackout Runtime Estimates

Modeled as usable kWh × √(RTE) ÷ load kW (10 kWh × 98.0% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.

Single-Unit Outage Runtime Estimates for 350-10LC
Light Essentials (0.8 kW — fridge, Wi-Fi, lights)12.3 hrs
Standard Backup (1.5 kW — + sump/freezer/home office)6.5 hrs
Heavy Load / HVAC (4.5 kW continuous)2.2 hrs

Multi-Unit Stacking Matrix

Multi-Unit Battery Stacking Runtime Matrix for 350-10LC
UnitsTotal kWhCont. kW1.5 kW Backup4.5 kW HVAC
1×10.0 kWh7.6 kW6.5 hrs2.2 hrs
2×20.0 kWh15.2 kW13.1 hrs4.4 hrs
3×30.0 kWh22.8 kW19.6 hrs6.5 hrs
4×40.0 kWh30.4 kW26.1 hrs8.7 hrs

Outage Sizing Notes & FAQ — Kohler Co 350-10LC

When sizing a residential storage bank around the Kohler Co 350-10LC (10 kWh usable, 7.6 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 6.5 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.

How long will one Kohler Co 350-10LC run during a power outage?
Using one-way discharge efficiency (√96.1% ≈ 98.0%) on 10 kWh usable capacity without solar recharge, one 350-10LC delivers approximately 12.3 hours at a 0.8 kW light-essentials load (fridge, Wi-Fi, LED lights) or 6.5 hours at a 1.5 kW standard backup load.
Can the Kohler Co 350-10LC run a central air conditioner or heat pump?
A single unit supplies 7.6 kW continuous AC power, enough to sustain a 4.5 kW HVAC load for roughly 2.2 hours on battery alone. Always verify Locked Rotor Amps (LRA) compressor startup surge and install a soft-start kit if your condenser LRA exceeds inverter peak surge rating.
Is the Kohler Co 350-10LC AC-coupled or DC-coupled, and what safety listing does it hold?
In the CEC registry (snapshot 2026-11-23), this LFP (LiFePO4) battery carries UL 9540 (Ed. 1 : 2016) certification (tested by Intertek) and is listed as AC-coupled / paired via an external hybrid inverter. Confirm UL 9540 / UL 9540A spacing rules with your local AHJ.