Lion Energy Model #99990517 - 40.5kWh Sanctuary ESS (40.5 kWh)
8 kW, 40.5 kWh, 240 Vac LFP energy storage system. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .

Storage Specifications & Safety Listing
| Manufacturer | Lion Energy |
|---|---|
| Model Number (MPN) | Model #99990517 - 40.5kWh Sanctuary ESS |
| Battery Chemistry | LFP (LiFePO4) |
| Usable Energy Capacity | 40.5 kWh |
| Max Continuous Discharge | 8 kW |
| Round-Trip Efficiency (RTE) | 90% (Class Estimate — Not listed in CEC) |
| PV DC Input (DC-Coupled) | Yes (DC-Coupled Capable) |
| Nominal AC Grid Voltage | 240 Vac |
| Safety Listing | UL 9540 (Ed. 2 : 2020) |
| Certifying Laboratory | SGS |
Single-Unit Blackout Runtime Estimates
Modeled as usable kWh × √(RTE) ÷ load kW (40.5 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.
| Light Essentials (0.8 kW — fridge, Wi-Fi, lights) | 48 hrs |
|---|---|
| Standard Backup (1.5 kW — + sump/freezer/home office) | 25.6 hrs |
| Heavy Load / HVAC (4.5 kW continuous) | 8.5 hrs |
Multi-Unit Stacking Matrix
| Units | Total kWh | Cont. kW | 1.5 kW Backup | 4.5 kW HVAC |
|---|---|---|---|---|
| 1× | 40.5 kWh | 8.0 kW | 25.6 hrs | 8.5 hrs |
| 2× | 81.0 kWh | 16.0 kW | 51.2 hrs | 17.1 hrs |
| 3× | 121.5 kWh | 24.0 kW | 76.8 hrs | 25.6 hrs |
| 4× | 162.0 kWh | 32.0 kW | 102.5 hrs | 34.2 hrs |
Outage Sizing Notes & FAQ — Lion Energy Model #99990517 - 40.5kWh Sanctuary ESS
When sizing a residential storage bank around the Lion Energy Model #99990517 - 40.5kWh Sanctuary ESS (40.5 kWh usable, 8 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 25.6 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.