SolarJuice American S4A-A70 [11.5kWh] (11.5 kWh)
7 kW, 11.5 kWh, 240 Vac, LFP Energy Storage System. Source: CEC Energy Storage System List (Nov 2026) · CEC listing date: · Registry snapshot: .
![SolarJuice American S4A-A70 [11.5kWh] — Illustrative category photo — not this exact model (residential battery & home backup system)](/assets/images/tool-backup-power.webp)
Storage Specifications & Safety Listing
| Manufacturer | SolarJuice American |
|---|---|
| Model Number (MPN) | S4A-A70 [11.5kWh] |
| Battery Chemistry | LFP (LiFePO4) |
| Usable Energy Capacity | 11.5 kWh |
| Max Continuous Discharge | 7 kW |
| Round-Trip Efficiency (RTE) | 90% (Class Estimate — Not listed in CEC) |
| PV DC Input (DC-Coupled) | AC-Coupled / External Hybrid Inverter |
| Nominal AC Grid Voltage | 240 Vac |
| Safety Listing | UL 9540 (Ed. 1 : 2016) |
| Certifying Laboratory | CSA Group |
Single-Unit Blackout Runtime Estimates
Modeled as usable kWh × √(RTE) ÷ load kW (11.5 kWh × 94.9% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.
| Light Essentials (0.8 kW — fridge, Wi-Fi, lights) | 13.6 hrs |
|---|---|
| Standard Backup (1.5 kW — + sump/freezer/home office) | 7.3 hrs |
| Heavy Load / HVAC (4.5 kW continuous) | 2.4 hrs |
Multi-Unit Stacking Matrix
| Units | Total kWh | Cont. kW | 1.5 kW Backup | 4.5 kW HVAC |
|---|---|---|---|---|
| 1× | 11.5 kWh | 7.0 kW | 7.3 hrs | 2.4 hrs |
| 2× | 23.0 kWh | 14.0 kW | 14.5 hrs | 4.8 hrs |
| 3× | 34.5 kWh | 21.0 kW | 21.8 hrs | 7.3 hrs |
| 4× | 46.0 kWh | 28.0 kW | 29.1 hrs | 9.7 hrs |
Outage Sizing Notes & FAQ — SolarJuice American S4A-A70 [11.5kWh]
When sizing a residential storage bank around the SolarJuice American S4A-A70 [11.5kWh] (11.5 kWh usable, 7 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 7.3 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.