Tesla Energy Powerwall 3 (1707000-XX-Y) (13.5 kWh)
13.5 kWh / 11.5 kW LFP (LiFePO4) Residential Energy Storage System (UL 9540 (Ed. 3) / UL 1741-SB). AC-coupled/integrated inverter CEC continuous 10–11.5 kW, 89% AC-to-AC / 97.5% solar-to-home. Source: Tesla Spec & CEC ESS Registry (2026) · CEC listing date: · Registry snapshot: .

Storage Specifications & Safety Listing
| Manufacturer | Tesla Energy |
|---|---|
| Model Number (MPN) | Powerwall 3 (1707000-XX-Y) |
| Battery Chemistry | LFP (LiFePO4) |
| Usable Energy Capacity | 13.5 kWh |
| Max Continuous Discharge | 11.5 kW |
| Round-Trip Efficiency (RTE) | 97.5% |
| PV DC Input (DC-Coupled) | Yes (DC-Coupled Capable) |
| Nominal AC Grid Voltage | 240 Vac |
| Safety Listing | UL 9540 (Ed. 3) / UL 1741-SB |
| Certifying Laboratory | UL / NRTL |
Single-Unit Blackout Runtime Estimates
Modeled as usable kWh × √(RTE) ÷ load kW (13.5 kWh × 98.7% one-way discharge efficiency) with no solar recharge. Reserve buffer (e.g., 10%–20% user reserve) reduces usable outage hours proportionally.
| Light Essentials (0.8 kW — fridge, Wi-Fi, lights) | 16.7 hrs |
|---|---|
| Standard Backup (1.5 kW — + sump/freezer/home office) | 8.9 hrs |
| Heavy Load / HVAC (4.5 kW continuous) | 3 hrs |
Multi-Unit Stacking Matrix
| Units | Total kWh | Cont. kW | 1.5 kW Backup | 4.5 kW HVAC |
|---|---|---|---|---|
| 1× | 13.5 kWh | 11.5 kW | 8.9 hrs | 3.0 hrs |
| 2× | 27.0 kWh | 23.0 kW | 17.8 hrs | 5.9 hrs |
| 3× | 40.5 kWh | 34.5 kW | 26.7 hrs | 8.9 hrs |
| 4× | 54.0 kWh | 46.0 kW | 35.5 hrs | 11.8 hrs |
Outage Sizing Notes & FAQ — Tesla Energy Powerwall 3 (1707000-XX-Y)
When sizing a residential storage bank around the Tesla Energy Powerwall 3 (1707000-XX-Y) (13.5 kWh usable, 11.5 kW continuous), evaluate both energy duration (kWh) and peak starting current (kW / LRA). On a typical 1.5 kW essential-loads subpanel, one unit delivers roughly 8.9 hours overnight before morning solar recharge begins. Under California NEM 3.0 or Time-of-Use (TOU) arbitrage rates, shifting 8–12 kWh per evening peak window aligns well with a single- or dual-unit stack, while multi-day winter storms or whole-home 240V central AC generally require 1× stacked units plus a compressor soft-start kit.