Solar Inverter Fault & Error Code Reference (SolarEdge, Enphase IQ8, Generac)
SolarEdge Error 18xB6 (DC Isolation) and 3x6E (AFCI) require professional rooftop DC testing, while Enphase Gateway offline alerts are often simple Wi-Fi or AC breaker resets.

Most Frequent US Residential Solar Inverter Fault Codes
| Brand | Code / Alert | Root Cause | Safe Action |
|---|---|---|---|
| SolarEdge | 18xB6 / 18xB7 | Low DC Isolation Resistance (Riso) | Leave DC off; tech Megger-tests rooftop connectors |
| SolarEdge | 3x6E / AFCI | DC Arc-Fault detected | Clear once; if repeats, inspect optimizer/MC4 splices |
| SolarEdge | 2x / Grid V High | AC voltage >264V on sunny noon | Verify AC wire gauge & utility transformer tap |
| Enphase IQ8 | Microinverters Not Reporting | PLC noise or Gateway Wi-Fi drop | Check combiner breakers & Envoy Wi-Fi (often still producing) |
| Generac PWRcell | Error 7000 / 7100 | SnapRS rapid-shutdown mismatch | Schedule certified PWRcell service replacement |
First Check: Is Production Dead, or Just the Monitoring App?
A large share of "dead solar" service calls turn out to be a home Wi-Fi password change or offline cellular modem inside the monitoring gateway rather than a hardware failure. Before calling a technician, walk outside at noon on a sunny day and check your utility bi-directional net meter: if the directional arrow points left (exporting kWh), your panels are still generating power and only the telemetry link needs reconnecting.
Why You Must Never Ignore DC Isolation (Riso) or AFCI Faults
Unlike residential 120V AC circuits, string solar arrays run at 350V to 600V continuous DC during daylight — an arc will not self-extinguish at zero-crossing. Moisture ingress inside pinched MC4 connectors or squirrel-chewed rooftop wiring triggers Riso/AFCI shutdowns specifically to prevent rooftop fires.
Sources & Standards Referenced
- NFPA 70 Article 690 (Solar Photovoltaic Systems) — NEC 690.11 AFCI arc-fault protection and 690.12 rapid shutdown standards
- CEC Solar Inverter Equipment List — UL 1741-SB smart inverter certification and grid-voltage trip windows