DiagnosticsUpdated · 4 min read

Solar Inverter Fault & Error Code Reference (SolarEdge, Enphase IQ8, Generac)

SolarEdge Error 18xB6 (DC Isolation) and 3x6E (AFCI) require professional rooftop DC testing, while Enphase Gateway offline alerts are often simple Wi-Fi or AC breaker resets.

Two residential wall-mounted solar string inverters with neatly bent EMT metal conduit on shaded house siding
High-Voltage DC Risk
350 – 600V DC
Avg Service Truck Roll
$250 – $450
Out-of-Warranty Swap
$1,800 – $2,900
Brands Covered
SolarEdge / Enphase / Generac

Most Frequent US Residential Solar Inverter Fault Codes

Most Frequent US Residential Solar Inverter Fault Codes
BrandCode / AlertRoot CauseSafe Action
SolarEdge18xB6 / 18xB7Low DC Isolation Resistance (Riso)Leave DC off; tech Megger-tests rooftop connectors
SolarEdge3x6E / AFCIDC Arc-Fault detectedClear once; if repeats, inspect optimizer/MC4 splices
SolarEdge2x / Grid V HighAC voltage >264V on sunny noonVerify AC wire gauge & utility transformer tap
Enphase IQ8Microinverters Not ReportingPLC noise or Gateway Wi-Fi dropCheck combiner breakers & Envoy Wi-Fi (often still producing)
Generac PWRcellError 7000 / 7100SnapRS rapid-shutdown mismatchSchedule certified PWRcell service replacement

First Check: Is Production Dead, or Just the Monitoring App?

A large share of "dead solar" service calls turn out to be a home Wi-Fi password change or offline cellular modem inside the monitoring gateway rather than a hardware failure. Before calling a technician, walk outside at noon on a sunny day and check your utility bi-directional net meter: if the directional arrow points left (exporting kWh), your panels are still generating power and only the telemetry link needs reconnecting.

Why You Must Never Ignore DC Isolation (Riso) or AFCI Faults

Unlike residential 120V AC circuits, string solar arrays run at 350V to 600V continuous DC during daylight — an arc will not self-extinguish at zero-crossing. Moisture ingress inside pinched MC4 connectors or squirrel-chewed rooftop wiring triggers Riso/AFCI shutdowns specifically to prevent rooftop fires.

Sources & Standards Referenced

Frequently Asked Questions

How do I safely reboot my solar inverter once?
Turn off the AC solar breaker/disconnect first, wait 10 seconds, switch the inverter DC rotary switch to OFF, wait 5 minutes for capacitors to discharge, then restore DC first and AC second.
Are SolarEdge inverters covered after 12 years?
Standard SolarEdge warranties run 12 years (extendable to 20–25 years if purchased early). Labor truck rolls ($250–$450) are typically not covered by manufacturer warranties.