ABB / FIMER UNO-DM-4.6-TL-PLUS-US-SE-RA (4.6 kW)
4.6 kW, 240 Vac Grid Support Utility Interactive Inverter with arc detector, Ethernet LAN, and Rapid Shutdown power supply. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
4.6 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
25A @ 240V
Inverter Engineering Tools
Legacy / Replacement Reference: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | ABB / FIMER |
|---|---|
| Model Number (MPN) | UNO-DM-4.6-TL-PLUS-US-SE-RA |
| Inverter Topology | String Inverter |
| Continuous AC Power (Paco) | 4.6 kW (4,600 W) |
| Nominal DC Input (Pdco) | 4,783 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 200 – 480 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 480 Vdc |
| Max DC Input Current | 13.5 A |
| Night Tare Loss | 1 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 19.2 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 24.0 A |
| Minimum Standard Breaker | 25 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (5.06–6.21 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 13–16 panels | 5.2–6.4 kW DC |
| 440W | 12–14 panels | 5.3–6.2 kW DC |
| 550W | 9–11 panels | 5.0–6.0 kW DC |
CEC-Listed 240V Equivalents to ABB / FIMER UNO-DM-4.6-TL-PLUS-US-SE-RA
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (4.6 kW String Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for ABB / FIMER UNO-DM-4.6-TL-PLUS-US-SE-RA
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 6–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 6–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 6–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 6–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 6–8 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–6 per string (-10°C) | Verify Pair |
Engineering FAQ — ABB / FIMER UNO-DM-4.6-TL-PLUS-US-SE-RA
What size circuit breaker does the ABB / FIMER UNO-DM-4.6-TL-PLUS-US-SE-RA require under NEC 705.12?
At 4.6 kW continuous AC output on 240V (19.2A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the ABB / FIMER UNO-DM-4.6-TL-PLUS-US-SE-RA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.6 kW unit with 5.06 kW to 6.21 kW DC of solar modules without exceeding 480V cold Voc.