ABB / FIMER official logoLegacy / Replacement ReferenceString

ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA (6 kW)

6.0 kW (240Vac) Grid Support Utility Interactive Inverter w/ arc detector, Zigbee, Revenue Grade Meter, RSD PSU. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6 kW
CEC Weighted Eff.
97%
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Legacy / Replacement Reference: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 6 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA Electrical and Grid-Support Specifications
ManufacturerABB / FIMER
Model Number (MPN)UNO-DM-6.0-TL-PLUS-US-SZM-RA
Inverter TopologyString Inverter
Continuous AC Power (Paco)6 kW (6,000 W)
Nominal DC Input (Pdco)6,184 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current17.4 A
Night Tare Loss1.3 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for UNO-DM-6.0-TL-PLUS-US-SZM-RA
Max Continuous AC Current25 A @ 240V
125% Continuous Duty Current31.3 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.6–8.1 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for UNO-DM-6.0-TL-PLUS-US-SZM-RA
Panel ClassRecommended QtyDC Array / Ratio
400W17–20 panels6.8–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

CEC-Listed 240V Equivalents to ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (6 kW String Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V6 kW
Fronius · String

Primo 6.0-1 208-240

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V6 kW
SMA Solar · String

SB6.0-1SP-US-40

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V6 kW
Solis (Ginlong) · String

1P6K-4G-US

CEC Efficiency: 97.5%
Datasheet →

Compatible Solar Panels for ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA

What size circuit breaker does the ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA require under NEC 705.12?
At 6 kW continuous AC output on 240V (25A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the ABB / FIMER UNO-DM-6.0-TL-PLUS-US-SZM-RA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6 kW unit with 6.6 kW to 8.1 kW DC of solar modules without exceeding 480V cold Voc.

More ABB / FIMER Inverters

UNO-DM-6.0-TL-PLUS-US-SB-RA-QU (6 kW)UNO-DM-6.0-TL-PLUS-US-SC-RA (6 kW)UNO-DM-6.0-TL-PLUS-US-SE-RA (6 kW)UNO-7.6-TL-OUTD-S-US-A (7.6 kW)UNO-7.6-TL-OUTD-S-US-Z-A (7.6 kW)UNO-7.6-TL-OUTD-S-US-Z-M-A (7.6 kW)All ABB / FIMER Equipment →