AN CEC-Listed · 240V ResidentialHybridBattery Hybrid

Afore New Energy Technology (Shanghai) AF6K-DH (5.995 kW)

6 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.995 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
220–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Afore New Energy Technology (Shanghai) AF6K-DH — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–480 Vdc 220V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.995 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Afore New Energy Technology (Shanghai) AF6K-DH Electrical and Grid-Support Specifications
ManufacturerAfore New Energy Technology (Shanghai)
Model Number (MPN)AF6K-DH
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.995 kW (5,995 W)
Nominal DC Input (Pdco)6,143 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window220 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current17.1 A
Night Tare Loss0.55 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for AF6K-DH
Max Continuous AC Current25 A @ 240V
125% Continuous Duty Current31.3 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.59–8.09 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for AF6K-DH
Panel ClassRecommended QtyDC Array / Ratio
400W16–20 panels6.4–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for Afore New Energy Technology (Shanghai) AF6K-DH

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Afore New Energy Technology (Shanghai) AF6K-DH
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Afore New Energy Technology (Shanghai) AF6K-DH

What size circuit breaker does the Afore New Energy Technology (Shanghai) AF6K-DH require under NEC 705.12?
At 5.995 kW continuous AC output on 240V (25A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Afore New Energy Technology (Shanghai) AF6K-DH?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.995 kW unit with 6.59 kW to 8.09 kW DC of solar modules without exceeding 480V cold Voc.

More Afore New Energy Technology (Shanghai) Inverters

AF9.6K-DH (9.592 kW)AF4.6K-DH (4.6 kW)AF5K-DH (4.998 kW)AF7K-DH (6.996 kW)AF7.6K-DH (7.599 kW)AF8K-DH (7.999 kW)All Afore New Energy Technology (Shanghai) Equipment →