AE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Amensolar Ess N3H-X16US (16.199 kW)

16.0 kW, 240Vac Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
16.199 kW
CEC Weighted Eff.
96%
MPPT / Max DC
220–430V / 430V
NEC 705.12 Breaker
90A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Amensolar Ess N3H-X16US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–430 Vdc 220V 430V MAX 430V PV DC INPUT ≤ 430V DC 16.199 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 90A BRKR

Electrical & Grid-Support Datasheet

Amensolar Ess N3H-X16US Electrical and Grid-Support Specifications
ManufacturerAmensolar Ess
Model Number (MPN)N3H-X16US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)16.199 kW (16,199 W)
Nominal DC Input (Pdco)16,830 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window220 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current46.8 A
Night Tare Loss16.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for N3H-X16US
Max Continuous AC Current67.5 A @ 240V
125% Continuous Duty Current84.4 A
Minimum Standard Breaker90 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (17.82–21.87 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for N3H-X16US
Panel ClassRecommended QtyDC Array / Ratio
400W45–55 panels18.0–22.0 kW DC
440W41–50 panels18.0–22.0 kW DC
550W32–40 panels17.6–22.0 kW DC

Compatible Solar Panels for Amensolar Ess N3H-X16US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Amensolar Ess N3H-X16US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Amensolar Ess N3H-X16US

What size circuit breaker does the Amensolar Ess N3H-X16US require under NEC 705.12?
At 16.199 kW continuous AC output on 240V (67.5A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Amensolar Ess N3H-X16US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 16.199 kW unit with 17.82 kW to 21.87 kW DC of solar modules without exceeding 430V cold Voc.

More Amensolar Ess Inverters

N3H-X8US (8.084 kW)N3H-X10US (10.177 kW)N3H-X12US (12.214 kW)N3H-X5US (5.09 kW)N3H-X6.0-US (6.117 kW)N3H-X7.6-US (7.765 kW)All Amensolar Ess Equipment →