BS CEC-Listed · Commercial / C&IHybridBattery Hybrid

Briggs & Stratton (SimpliPhi) SPHI-IN-6 (6.018 kW)

6 kW, 120 Vac Split Phase, Transformerless Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.018 kW
CEC Weighted Eff.
93.5%
MPPT / Max DC
250–500V / 500V
NEC 705.12 Breaker
70A @ 120V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Briggs & Stratton (SimpliPhi) SPHI-IN-6 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–500 Vdc 250V 500V MAX 500V PV DC INPUT ≤ 500V DC 6.018 kW · 93.5% CEC PV + BATTERY HYBRID AC OUTPUT 120V · 70A BRKR

Electrical & Grid-Support Datasheet

Briggs & Stratton (SimpliPhi) SPHI-IN-6 Electrical and Grid-Support Specifications
ManufacturerBriggs & Stratton (SimpliPhi)
Model Number (MPN)SPHI-IN-6
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.018 kW (6,018 W)
Nominal DC Input (Pdco)6,365 W
Nominal AC Voltage120 Vac (Split/Single-Phase)
CEC Weighted Efficiency93.5%
MPPT Operating Window250 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current17.2 A
Night Tare Loss43 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SPHI-IN-6
Max Continuous AC Current50.1 A @ 120V
125% Continuous Duty Current62.6 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.62–8.12 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SPHI-IN-6
Panel ClassRecommended QtyDC Array / Ratio
400W17–20 panels6.8–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

CEC-Listed 240V Equivalents to Briggs & Stratton (SimpliPhi) SPHI-IN-6

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (6.018 kW Hybrid Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V6.018 kW
Dyness · Hybrid

TX6K-HM

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V6.017 kW
Qcells (Hanwha) · Hybrid

Q.VOLT H6.0SX

CEC Efficiency: 97.5%
Datasheet →
CEC-Listed · 240V6.017 kW
SolaX Power · Hybrid

A1-HYB-6.0K-G2

CEC Efficiency: 97.5%
Datasheet →

Compatible Solar Panels for Briggs & Stratton (SimpliPhi) SPHI-IN-6

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Briggs & Stratton (SimpliPhi) SPHI-IN-6
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — Briggs & Stratton (SimpliPhi) SPHI-IN-6

What size circuit breaker does the Briggs & Stratton (SimpliPhi) SPHI-IN-6 require under NEC 705.12?
At 6.018 kW continuous AC output on 120V (50.1A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Briggs & Stratton (SimpliPhi) SPHI-IN-6?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.018 kW unit with 6.62 kW to 8.12 kW DC of solar modules without exceeding 500V cold Voc.