CS CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Cherry Solution CMI-1000S-SA (1.062 kW)

1062 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.062 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Cherry Solution CMI-1000S-SA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–50 Vdc 35V 50V MAX 50V PV DC INPUT ≤ 50V DC 1.062 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Cherry Solution CMI-1000S-SA Electrical and Grid-Support Specifications
ManufacturerCherry Solution
Model Number (MPN)CMI-1000S-SA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.062 kW (1,062 W)
Nominal DC Input (Pdco)1,102 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window35 – 50 Vdc (NREL SAM Measured)
Max DC Input Voltage50 Vdc
Max DC Input Current26.2 A
Night Tare Loss0.13 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for CMI-1000S-SA
Max Continuous AC Current4.4 A @ 240V
125% Continuous Duty Current5.5 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.17–1.43 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for CMI-1000S-SA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.38× DC/AC)
440W1 panel1:1 pairing (0.41× DC/AC)
550W1 panel1:1 pairing (0.52× DC/AC)

Engineering FAQ — Cherry Solution CMI-1000S-SA

What size circuit breaker does the Cherry Solution CMI-1000S-SA require under NEC 705.12?
At 1.062 kW continuous AC output on 240V (4.4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Cherry Solution CMI-1000S-SA?
As a 1062W microinverter, it pairs 1:1 with panels rated roughly 1115W to 1540W STC.

More Cherry Solution Inverters

CMI-600S-SA (0.604 kW)CMI-800S-SA (0.8 kW)All Cherry Solution Equipment →