CC CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

CPS (Chint Power Systems) ECH11.4KTL/US (11.36 kW)

11.4 kW, 240Vac, Bi-directional, Transformerless, Hybrid Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.36 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
CPS (Chint Power Systems) ECH11.4KTL/US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.36 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

CPS (Chint Power Systems) ECH11.4KTL/US Electrical and Grid-Support Specifications
ManufacturerCPS (Chint Power Systems)
Model Number (MPN)ECH11.4KTL/US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.36 kW (11,360 W)
Nominal DC Input (Pdco)11,768 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current31.8 A
Night Tare Loss30 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for ECH11.4KTL/US
Max Continuous AC Current47.3 A @ 240V
125% Continuous Duty Current59.1 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.5–15.34 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for ECH11.4KTL/US
Panel ClassRecommended QtyDC Array / Ratio
400W31–38 panels12.4–15.2 kW DC
440W28–35 panels12.3–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for CPS (Chint Power Systems) ECH11.4KTL/US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for CPS (Chint Power Systems) ECH11.4KTL/US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — CPS (Chint Power Systems) ECH11.4KTL/US

What size circuit breaker does the CPS (Chint Power Systems) ECH11.4KTL/US require under NEC 705.12?
At 11.36 kW continuous AC output on 240V (47.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the CPS (Chint Power Systems) ECH11.4KTL/US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.36 kW unit with 12.5 kW to 15.34 kW DC of solar modules without exceeding 480V cold Voc.

More CPS (Chint Power Systems) Inverters

ECH12KTL/US (11.99 kW)ECH7.6KTL/US (7.57 kW)ECH9.6KTL/US (9.54 kW)All CPS (Chint Power Systems) Equipment →