DE CEC-Listed · 240V ResidentialHybridBattery Hybrid

Darfon Electronics H7xxxxxx (9.604 kW)

9600 W, 240 Vac, Grid Support Utility Interactive Inverter, where x = 0-9, A-Z or blank, (0-9 for color; A-Z for customer). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.604 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
230–410V / 410V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Darfon Electronics H7xxxxxx — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 230–410 Vdc 230V 410V MAX 410V PV DC INPUT ≤ 410V DC 9.604 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

Darfon Electronics H7xxxxxx Electrical and Grid-Support Specifications
ManufacturerDarfon Electronics
Model Number (MPN)H7xxxxxx
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.604 kW (9,604 W)
Nominal DC Input (Pdco)9,949 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window230 – 410 Vdc (NREL SAM Measured)
Max DC Input Voltage410 Vdc
Max DC Input Current27.6 A
Night Tare Loss26.9 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for H7xxxxxx
Max Continuous AC Current40 A @ 240V
125% Continuous Duty Current50.0 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.56–12.97 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for H7xxxxxx
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–24 panels10.4–13.2 kW DC

Compatible Solar Panels for Darfon Electronics H7xxxxxx

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Darfon Electronics H7xxxxxx
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–5 per string (-10°C)Verify Pair

Engineering FAQ — Darfon Electronics H7xxxxxx

What size circuit breaker does the Darfon Electronics H7xxxxxx require under NEC 705.12?
At 9.604 kW continuous AC output on 240V (40A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Darfon Electronics H7xxxxxx?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.604 kW unit with 10.56 kW to 12.97 kW DC of solar modules without exceeding 410V cold Voc.

More Darfon Electronics Inverters

HB51xxxxxx (4.665 kW)H5001xxxxxx (4.844 kW)H5000xxxxxx (5.074 kW)All Darfon Electronics Equipment →