DC CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

dcbel Ara (DBHS-ARxx-xx) (7.624 kW)

7.62 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.624 kW
CEC Weighted Eff.
92%
MPPT / Max DC
450–470V / 470V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
dcbel Ara (DBHS-ARxx-xx) — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 450–470 Vdc 450V 470V MAX 470V PV DC INPUT ≤ 470V DC 7.624 kW · 92% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

dcbel Ara (DBHS-ARxx-xx) Electrical and Grid-Support Specifications
Manufacturerdcbel
Model Number (MPN)Ara (DBHS-ARxx-xx)
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.624 kW (7,624 W)
Nominal DC Input (Pdco)8,292 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency92%
MPPT Operating Window450 – 470 Vdc (NREL SAM Measured)
Max DC Input Voltage470 Vdc
Max DC Input Current18 A
Night Tare Loss32.5 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryTUV SUD America
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Ara (DBHS-ARxx-xx)
Max Continuous AC Current31.8 A @ 240V
125% Continuous Duty Current39.8 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.39–10.29 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Ara (DBHS-ARxx-xx)
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Engineering FAQ — dcbel Ara (DBHS-ARxx-xx)

What size circuit breaker does the dcbel Ara (DBHS-ARxx-xx) require under NEC 705.12?
At 7.624 kW continuous AC output on 240V (31.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the dcbel Ara (DBHS-ARxx-xx)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.624 kW unit with 8.39 kW to 10.29 kW DC of solar modules without exceeding 470V cold Voc.