EF CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

EcoFlow EF-PCS-24 (11.444 kW)

11.5 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.444 kW
CEC Weighted Eff.
96%
MPPT / Max DC
320–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
EcoFlow EF-PCS-24 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 320–480 Vdc 320V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.444 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

EcoFlow EF-PCS-24 Electrical and Grid-Support Specifications
ManufacturerEcoFlow
Model Number (MPN)EF-PCS-24
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.444 kW (11,444 W)
Nominal DC Input (Pdco)24,820 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window320 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current62 A
Night Tare Loss115.86 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for EF-PCS-24
Max Continuous AC Current47.7 A @ 240V
125% Continuous Duty Current59.6 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.59–15.45 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for EF-PCS-24
Panel ClassRecommended QtyDC Array / Ratio
400W31–39 panels12.4–15.6 kW DC
440W29–35 panels12.8–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for EcoFlow EF-PCS-24

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for EcoFlow EF-PCS-24
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-560-BTC-HV560 W48.81 V9–9 per string (-10°C)Verify Pair
Silfab Solar SIL-540XM540 W47.95 V9–9 per string (-10°C)Verify Pair
Canadian Solar CS6.2-48TM-430H430 W35 V13–13 per string (-10°C)Verify Pair
REC Solar REC430AA Pure 2430 W49 V9–9 per string (-10°C)Verify Pair

Engineering FAQ — EcoFlow EF-PCS-24

What size circuit breaker does the EcoFlow EF-PCS-24 require under NEC 705.12?
At 11.444 kW continuous AC output on 240V (47.7A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the EcoFlow EF-PCS-24?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.444 kW unit with 12.59 kW to 15.45 kW DC of solar modules without exceeding 480V cold Voc.