EcoFlow EF-PCS-24 (11.444 kW)
11.5 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
11.444 kW
CEC Weighted Eff.
96%
MPPT / Max DC
320–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | EcoFlow |
|---|---|
| Model Number (MPN) | EF-PCS-24 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 11.444 kW (11,444 W) |
| Nominal DC Input (Pdco) | 24,820 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 96% |
| MPPT Operating Window | 320 – 480 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 480 Vdc |
| Max DC Input Current | 62 A |
| Night Tare Loss | 115.86 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 47.7 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 59.6 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (12.59–15.45 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 31–39 panels | 12.4–15.6 kW DC |
| 440W | 29–35 panels | 12.8–15.4 kW DC |
| 550W | 23–28 panels | 12.7–15.4 kW DC |
Compatible Solar Panels for EcoFlow EF-PCS-24
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-560-BTC-HV | 560 W | 48.81 V | 9–9 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540XM | 540 W | 47.95 V | 9–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-430H | 430 W | 35 V | 13–13 per string (-10°C) | Verify Pair |
| REC Solar REC430AA Pure 2 | 430 W | 49 V | 9–9 per string (-10°C) | Verify Pair |
Engineering FAQ — EcoFlow EF-PCS-24
What size circuit breaker does the EcoFlow EF-PCS-24 require under NEC 705.12?
At 11.444 kW continuous AC output on 240V (47.7A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the EcoFlow EF-PCS-24?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.444 kW unit with 12.59 kW to 15.45 kW DC of solar modules without exceeding 480V cold Voc.