EG4 Electronics official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

EG4 Electronics IV-13000-HYB-AW-FX-xx (12.997 kW)

12.9 kW, 240 Vac Grid Support Utility Interactive FlexBOSS18 Inverter, where xx = 00-99. Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
12.997 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
250–440V / 440V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
EG4 Electronics IV-13000-HYB-AW-FX-xx — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–440 Vdc 250V 440V MAX 440V PV DC INPUT ≤ 440V DC 12.997 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

EG4 Electronics IV-13000-HYB-AW-FX-xx Electrical and Grid-Support Specifications
ManufacturerEG4 Electronics
Model Number (MPN)IV-13000-HYB-AW-FX-xx
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)12.997 kW (12,997 W)
Nominal DC Input (Pdco)13,496 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window250 – 440 Vdc (NREL SAM Measured)
Max DC Input Voltage440 Vdc
Max DC Input Current37.5 A
Night Tare Loss29.57 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IV-13000-HYB-AW-FX-xx
Max Continuous AC Current54.2 A @ 240V
125% Continuous Duty Current67.8 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (14.3–17.55 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IV-13000-HYB-AW-FX-xx
Panel ClassRecommended QtyDC Array / Ratio
400W36–44 panels14.4–17.6 kW DC
440W33–40 panels14.5–17.6 kW DC
550W26–32 panels14.3–17.6 kW DC

Compatible Solar Panels for EG4 Electronics IV-13000-HYB-AW-FX-xx

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for EG4 Electronics IV-13000-HYB-AW-FX-xx
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — EG4 Electronics IV-13000-HYB-AW-FX-xx

What size circuit breaker does the EG4 Electronics IV-13000-HYB-AW-FX-xx require under NEC 705.12?
At 12.997 kW continuous AC output on 240V (54.2A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the EG4 Electronics IV-13000-HYB-AW-FX-xx?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12.997 kW unit with 14.3 kW to 17.55 kW DC of solar modules without exceeding 440V cold Voc.

More EG4 Electronics Inverters

IV-16000-HYB-AW-FX-xx (16.153 kW)IV-8000-HYB-AW (7.863 kW)18KPV-12LV (11.933 kW)All EG4 Electronics Equipment →