Enphase Energy IQ7X-96-E-US (0.315 kW)
315 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.315 kW
CEC Weighted Eff.
97%
MPPT / Max DC
45–64V / 64V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Enphase Energy |
|---|---|
| Model Number (MPN) | IQ7X-96-E-US |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.315 kW (315 W) |
| Nominal DC Input (Pdco) | 325 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 45 – 64 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 64 Vdc |
| Max DC Input Current | 6 A |
| Night Tare Loss | 0.03 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | UL |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1.3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 1.6 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.35–0.43 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.27× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.40× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.75× DC/AC) |
Compatible Solar Panels for Enphase Energy IQ7X-96-E-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-500-BTB-BG | 500 W | 44 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | DC/AC 1.51 (1 panel/input) | Verify Pair |
| Mission Solar MSX10-460HN0B {C} | 460 W | 39.3 V | DC/AC 1.46 (1 panel/input) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | DC/AC 1.46 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | DC/AC 1.41 (1 panel/input) | Verify Pair |
| Boviet Solar BVM7610M-490-H-HC-BF | 490 W | 44.58 V | DC/AC 1.56 (1 panel/input) | Verify Pair |
Engineering FAQ — Enphase Energy IQ7X-96-E-US
What size circuit breaker does the Enphase Energy IQ7X-96-E-US require under NEC 705.12?
At 0.315 kW continuous AC output on 240V (1.3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ7X-96-E-US?
As a 315W microinverter, it pairs 1:1 with panels rated roughly 331W to 457W STC.