Enphase Energy IQ8M-72-M-US (0.325 kW)
0.325 kW, 240 Vac Grid Support Utility Interactive Microinverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.325 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
30–45V / 45V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Enphase Energy |
|---|---|
| Model Number (MPN) | IQ8M-72-M-US |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.325 kW (325 W) |
| Nominal DC Input (Pdco) | 335 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 30 – 45 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 45 Vdc |
| Max DC Input Current | 8.9 A |
| Night Tare Loss | 0.02 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | UL |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1.4 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 1.8 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.36–0.44 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.23× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.35× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.69× DC/AC) |
Compatible Solar Panels for Enphase Energy IQ8M-72-M-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Mission Solar MSH10-520HT4T {B} | 520 W | 48.9 V | DC/AC 1.60 (1 panel/input) | Verify Pair |
| Canadian Solar CS6W-520MB-AG | 520 W | 48.4 V | DC/AC 1.60 (1 panel/input) | Verify Pair |
| SEG Solar SEG-515-BTC-BG | 515 W | 47.03 V | DC/AC 1.58 (1 panel/input) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | DC/AC 1.46 (1 panel/input) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | DC/AC 1.42 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | DC/AC 1.37 (1 panel/input) | Verify Pair |
Engineering FAQ — Enphase Energy IQ8M-72-M-US
What size circuit breaker does the Enphase Energy IQ8M-72-M-US require under NEC 705.12?
At 0.325 kW continuous AC output on 240V (1.4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ8M-72-M-US?
As a 325W microinverter, it pairs 1:1 with panels rated roughly 341W to 471W STC.