Enphase Energy IQ8P-3P-72-E-US (0.475 kW)
0.475 kW, 208 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.475 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
36–53V / 53V
NEC 705.12 Breaker
15A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Enphase Energy |
|---|---|
| Model Number (MPN) | IQ8P-3P-72-E-US |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.475 kW (475 W) |
| Nominal DC Input (Pdco) | 489 W |
| Nominal AC Voltage | 208 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 36 – 53 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 53 Vdc |
| Max DC Input Current | 10.9 A |
| Night Tare Loss | 0.06 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | UL |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1.3 A @ 208V |
|---|---|
| 125% Continuous Duty Current | 1.6 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.52–0.64 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.84× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.93× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.16× DC/AC) |
CEC-Listed 240V Equivalents to Enphase Energy IQ8P-3P-72-E-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (0.475 kW Microinverter) and can be added directly to your US System Kit:
Compatible Solar Panels for Enphase Energy IQ8P-3P-72-E-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | DC/AC 1.22 (1 panel/input) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | DC/AC 1.22 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | DC/AC 1.21 (1 panel/input) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | DC/AC 1.18 (1 panel/input) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | DC/AC 1.17 (1 panel/input) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | DC/AC 1.00 (1 panel/input) | Verify Pair |
Engineering FAQ — Enphase Energy IQ8P-3P-72-E-US
What size circuit breaker does the Enphase Energy IQ8P-3P-72-E-US require under NEC 705.12?
At 0.475 kW continuous AC output on 208V (1.3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ8P-3P-72-E-US?
As a 475W microinverter, it pairs 1:1 with panels rated roughly 499W to 689W STC.