Enphase Energy official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Enphase Energy IQ8X-80-M-DOM-US (0.384 kW)

0.384 kW, 240 Vac Grid Support Utility Interactive Microinverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.384 kW
CEC Weighted Eff.
97%
MPPT / Max DC
43–60V / 60V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Enphase Energy IQ8X-80-M-DOM-US — Real Enphase rooftop microinverter hardware
Real Enphase rooftop microinverter hardwareWikimedia Commons — File:Enphase M190.jpg (CC BY-SA 3.0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 43–60 Vdc 43V 60V MAX 60V PV DC INPUT ≤ 60V DC 0.384 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Enphase Energy IQ8X-80-M-DOM-US Electrical and Grid-Support Specifications
ManufacturerEnphase Energy
Model Number (MPN)IQ8X-80-M-DOM-US
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.384 kW (384 W)
Nominal DC Input (Pdco)392 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window43 – 60 Vdc (NREL SAM Measured)
Max DC Input Voltage60 Vdc
Max DC Input Current7.6 A
Night Tare Loss0.03 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryUL
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IQ8X-80-M-DOM-US
Max Continuous AC Current1.6 A @ 240V
125% Continuous Duty Current2.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.42–0.52 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IQ8X-80-M-DOM-US
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.04× DC/AC)
440W1 panel1:1 pairing (1.15× DC/AC)
550W1 panel1:1 pairing (1.43× DC/AC)

Compatible Solar Panels for Enphase Energy IQ8X-80-M-DOM-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Enphase Energy IQ8X-80-M-DOM-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.51 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.51 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.50 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.46 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.45 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.24 (1 panel/input)Verify Pair

Engineering FAQ — Enphase Energy IQ8X-80-M-DOM-US

What size circuit breaker does the Enphase Energy IQ8X-80-M-DOM-US require under NEC 705.12?
At 0.384 kW continuous AC output on 240V (1.6A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ8X-80-M-DOM-US?
As a 384W microinverter, it pairs 1:1 with panels rated roughly 403W to 557W STC.

More Enphase Energy Inverters