Enphase Energy official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)Battery Hybrid

Enphase Energy IQ8X-BAT-US-NB (0.315 kW)

315 VA, 240 V, Grid Support Utility Interactive Microinverter for use in Enphase's energy storage system. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.315 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
52–74V / 74V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Enphase Energy IQ8X-BAT-US-NB — Real Enphase rooftop microinverter hardware
Real Enphase rooftop microinverter hardwareWikimedia Commons — File:Enphase M190.jpg (CC BY-SA 3.0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 52–74 Vdc 52V 74V MAX 74V PV DC INPUT ≤ 74V DC 0.315 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Enphase Energy IQ8X-BAT-US-NB Electrical and Grid-Support Specifications
ManufacturerEnphase Energy
Model Number (MPN)IQ8X-BAT-US-NB
Inverter TopologyMicroinverter (PV + Battery Hybrid)
Continuous AC Power (Paco)0.315 kW (315 W)
Nominal DC Input (Pdco)324 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window52 – 74 Vdc (NREL SAM Measured)
Max DC Input Voltage74 Vdc
Max DC Input Current5.1 A
Night Tare Loss0.02 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryUL
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IQ8X-BAT-US-NB
Max Continuous AC Current1.3 A @ 240V
125% Continuous Duty Current1.6 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.35–0.43 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IQ8X-BAT-US-NB
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.27× DC/AC)
440W1 panel1:1 pairing (1.40× DC/AC)
550W1 panel1:1 pairing (1.75× DC/AC)

Compatible Solar Panels for Enphase Energy IQ8X-BAT-US-NB

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Enphase Energy IQ8X-BAT-US-NB
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-500-BTB-BG500 W44 VDC/AC 1.59 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.51 (1 panel/input)Verify Pair
Mission Solar MSX10-460HN0B {C}460 W39.3 VDC/AC 1.46 (1 panel/input)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 VDC/AC 1.46 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 VDC/AC 1.41 (1 panel/input)Verify Pair
Boviet Solar BVM7610M-490-H-HC-BF490 W44.58 VDC/AC 1.56 (1 panel/input)Verify Pair

Engineering FAQ — Enphase Energy IQ8X-BAT-US-NB

What size circuit breaker does the Enphase Energy IQ8X-BAT-US-NB require under NEC 705.12?
At 0.315 kW continuous AC output on 240V (1.3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ8X-BAT-US-NB?
As a 315W microinverter, it pairs 1:1 with panels rated roughly 331W to 457W STC.

More Enphase Energy Inverters

IQ7X-96-2-US (0.315 kW)IQ7X-96-M-US (0.315 kW)IQ8X-BAT-US (0.315 kW)IQ8MC-72-2-US (0.32 kW)IQ8M-72-2-US (0.325 kW)IQ7A-72-2-US (0.349 kW)All Enphase Energy Equipment →