EE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet

Eternalplanet Energy HNA2-S11G5 (5.812 kW)

5.8 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.812 kW
CEC Weighted Eff.
96%
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Eternalplanet Energy HNA2-S11G5 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 5.812 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Eternalplanet Energy HNA2-S11G5 Electrical and Grid-Support Specifications
ManufacturerEternalplanet Energy
Model Number (MPN)HNA2-S11G5
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.812 kW (5,812 W)
Nominal DC Input (Pdco)6,054 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design
Max DC Input Voltage600 Vdc
Max DC Input Current18.6 A
Night Tare Loss20.14 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryTUV Rheinland of North America
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HNA2-S11G5
Max Continuous AC Current24.2 A @ 240V
125% Continuous Duty Current30.3 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.39–7.85 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HNA2-S11G5
Panel ClassRecommended QtyDC Array / Ratio
400W16–20 panels6.4–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–14 panels6.6–7.7 kW DC

Compatible Solar Panels for Eternalplanet Energy HNA2-S11G5

Test any of 3,007 panels with this inverter →
Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
Compatible Solar Panels for Eternalplanet Energy HNA2-S11G5
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Eternalplanet Energy HNA2-S11G5

What size circuit breaker does the Eternalplanet Energy HNA2-S11G5 require under NEC 705.12?
At 5.812 kW continuous AC output on 240V (24.2A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Eternalplanet Energy HNA2-S11G5?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.812 kW unit with 6.39 kW to 7.85 kW DC of solar modules without exceeding 600V cold Voc.

More Eternalplanet Energy Inverters

HNA2-S11G6 (11.349 kW)All Eternalplanet Energy Equipment →