Fronius official logoCEC-Listed · 240V ResidentialString

Fronius Symo 10.0-3 208-240 (9.995 kW)

10 kW, 240 Vac, three phase Grid Support Utility Interactive Inverter with arc detector and meter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.995 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
100–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fronius Symo 10.0-3 208-240 — Real Fronius solar inverter installation
Real Fronius solar inverter installationWikimedia Commons — File:Bregenz-Vorarlberger Kraftwerke-Inverter Test bay-Fronius Ohmpilot 9 0-3-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 100–480 Vdc 100V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.995 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Fronius Symo 10.0-3 208-240 Electrical and Grid-Support Specifications
ManufacturerFronius
Model Number (MPN)Symo 10.0-3 208-240
Inverter TopologyString Inverter
Continuous AC Power (Paco)9.995 kW (9,995 W)
Nominal DC Input (Pdco)10,341 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window100 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current27.9 A
Night Tare Loss0.8 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Symo 10.0-3 208-240
Max Continuous AC Current41.6 A @ 240V
125% Continuous Duty Current52.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.99–13.49 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Symo 10.0-3 208-240
Panel ClassRecommended QtyDC Array / Ratio
400W27–34 panels10.8–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Fronius Symo 10.0-3 208-240

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fronius Symo 10.0-3 208-240
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V3–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V3–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V3–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V3–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V3–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–6 per string (-10°C)Verify Pair

Engineering FAQ — Fronius Symo 10.0-3 208-240

What size circuit breaker does the Fronius Symo 10.0-3 208-240 require under NEC 705.12?
At 9.995 kW continuous AC output on 240V (41.6A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fronius Symo 10.0-3 208-240?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.995 kW unit with 10.99 kW to 13.49 kW DC of solar modules without exceeding 480V cold Voc.

More Fronius Inverters

Primo GEN24 7.7 208-240 (7.686 kW)Primo 8.2-1 208-240 (8.2 kW)Primo 10.0-1 208-240 (9.995 kW)Primo GEN24 10.0 208-240 (10.019 kW)Symo Advanced 10.0-3 208-240 (10.062 kW)Primo 11.4-1 208-240 (11.4 kW)All Fronius Equipment →