Fronius official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Fronius Primo GEN24 6.0 208-240 (6.004 kW)

6 kW, 240 Vac Grid Support Utility Interactive PV and Battery (requires purchasing of a software package) Inverter with arc detector, PLC transmitter, and meter. Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.004 kW
CEC Weighted Eff.
97%
MPPT / Max DC
230–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fronius Primo GEN24 6.0 208-240 — Real Fronius solar inverter installation
Real Fronius solar inverter installationWikimedia Commons — File:Bregenz-Vorarlberger Kraftwerke-Inverter Test bay-Fronius Ohmpilot 9 0-3-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 230–480 Vdc 230V 480V MAX 480V PV DC INPUT ≤ 480V DC 6.004 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Fronius Primo GEN24 6.0 208-240 Electrical and Grid-Support Specifications
ManufacturerFronius
Model Number (MPN)Primo GEN24 6.0 208-240
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.004 kW (6,004 W)
Nominal DC Input (Pdco)6,173 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window230 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current15.4 A
Night Tare Loss8.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Primo GEN24 6.0 208-240
Max Continuous AC Current25 A @ 240V
125% Continuous Duty Current31.3 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.6–8.11 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Primo GEN24 6.0 208-240
Panel ClassRecommended QtyDC Array / Ratio
400W17–20 panels6.8–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for Fronius Primo GEN24 6.0 208-240

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fronius Primo GEN24 6.0 208-240
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Fronius Primo GEN24 6.0 208-240

What size circuit breaker does the Fronius Primo GEN24 6.0 208-240 require under NEC 705.12?
At 6.004 kW continuous AC output on 240V (25A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Fronius Primo GEN24 6.0 208-240?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.004 kW unit with 6.6 kW to 8.11 kW DC of solar modules without exceeding 480V cold Voc.

More Fronius Inverters

Primo GEN24 5.0 208-240 SC (5 kW)Primo GEN24 5.0 208-240 (5.007 kW)Primo 6.0-1 208-240 (6 kW)Primo GEN24 6.0 208-240 SC (6.005 kW)Primo 7.6-1 208-240 (7.6 kW)Primo GEN24 7.7 208-240 (7.686 kW)All Fronius Equipment →