GT CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Global Tech China SSM-7.6-SPHYB-UL (7.647 kW)

7.6 kW, 240 Vac, Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.647 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Global Tech China SSM-7.6-SPHYB-UL — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.647 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Global Tech China SSM-7.6-SPHYB-UL Electrical and Grid-Support Specifications
ManufacturerGlobal Tech China
Model Number (MPN)SSM-7.6-SPHYB-UL
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.647 kW (7,647 W)
Nominal DC Input (Pdco)7,923 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current22 A
Night Tare Loss15 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SSM-7.6-SPHYB-UL
Max Continuous AC Current31.9 A @ 240V
125% Continuous Duty Current39.9 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.41–10.32 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SSM-7.6-SPHYB-UL
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Global Tech China SSM-7.6-SPHYB-UL

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Global Tech China SSM-7.6-SPHYB-UL
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Global Tech China SSM-7.6-SPHYB-UL

What size circuit breaker does the Global Tech China SSM-7.6-SPHYB-UL require under NEC 705.12?
At 7.647 kW continuous AC output on 240V (31.9A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Global Tech China SSM-7.6-SPHYB-UL?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.647 kW unit with 8.41 kW to 10.32 kW DC of solar modules without exceeding 480V cold Voc.

More Global Tech China Inverters

SSM-11.4-SPHYB-UL (10.14 kW)SSM-6.0-SPHYB-UL (6.149 kW)All Global Tech China Equipment →