GoodWe official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

GoodWe GEH6.0-1U-US10 (6.109 kW)

6 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.109 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
GoodWe GEH6.0-1U-US10 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 6.109 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

GoodWe GEH6.0-1U-US10 Electrical and Grid-Support Specifications
ManufacturerGoodWe
Model Number (MPN)GEH6.0-1U-US10
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)6.109 kW (6,109 W)
Nominal DC Input (Pdco)6,281 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current15.7 A
Night Tare Loss9.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GEH6.0-1U-US10
Max Continuous AC Current25.5 A @ 240V
125% Continuous Duty Current31.9 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.72–8.25 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GEH6.0-1U-US10
Panel ClassRecommended QtyDC Array / Ratio
400W17–21 panels6.8–8.4 kW DC
440W15–19 panels6.6–8.4 kW DC
550W12–15 panels6.6–8.3 kW DC

Engineering FAQ — GoodWe GEH6.0-1U-US10

What size circuit breaker does the GoodWe GEH6.0-1U-US10 require under NEC 705.12?
At 6.109 kW continuous AC output on 240V (25.5A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the GoodWe GEH6.0-1U-US10?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.109 kW unit with 6.72 kW to 8.25 kW DC of solar modules without exceeding 480V cold Voc.

More GoodWe Inverters

GEP6.0-1-US30 (5.998 kW)GEC6.0-1U-US20 (6.01 kW)GW6000A-BP (6.03 kW)GW6000A-ES (6.109 kW)GW6000A-MS (6.109 kW)GW7000A-ES (7.057 kW)All GoodWe Equipment →