GoodWe official logoCEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

GoodWe GW5000-MS-US30 (4.968 kW)

5 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
4.968 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
165–500V / 500V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
GoodWe GW5000-MS-US30 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 165–500 Vdc 165V 500V MAX 500V PV DC INPUT ≤ 500V DC 4.968 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

GoodWe GW5000-MS-US30 Electrical and Grid-Support Specifications
ManufacturerGoodWe
Model Number (MPN)GW5000-MS-US30
Inverter TopologyString Inverter
Continuous AC Power (Paco)4.968 kW (4,968 W)
Nominal DC Input (Pdco)5,136 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window165 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current13.5 A
Night Tare Loss4.5 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GW5000-MS-US30
Max Continuous AC Current20.7 A @ 240V
125% Continuous Duty Current25.9 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.46–6.71 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GW5000-MS-US30
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W12–15 panels5.3–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for GoodWe GW5000-MS-US30

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for GoodWe GW5000-MS-US30
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–7 per string (-10°C)Verify Pair

Engineering FAQ — GoodWe GW5000-MS-US30

What size circuit breaker does the GoodWe GW5000-MS-US30 require under NEC 705.12?
At 4.968 kW continuous AC output on 240V (20.7A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the GoodWe GW5000-MS-US30?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.968 kW unit with 5.46 kW to 6.71 kW DC of solar modules without exceeding 500V cold Voc.

More GoodWe Inverters

GEC11.4-1U-US20 (11.392 kW)GEP11.4-1-US30 (11.397 kW)GEP5.0-1-US30 (4.968 kW)GEC5.0-1U-US20 (4.983 kW)GW5000H-ES (4.989 kW)GEH5.0-1U-US20 (5.005 kW)All GoodWe Equipment →