GoodWe official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

GoodWe GW5000A-BP (5.031 kW)

5 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.031 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–495V / 495V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
GoodWe GW5000A-BP — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–495 Vdc 200V 495V MAX 495V PV DC INPUT ≤ 495V DC 5.031 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

GoodWe GW5000A-BP Electrical and Grid-Support Specifications
ManufacturerGoodWe
Model Number (MPN)GW5000A-BP
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.031 kW (5,031 W)
Nominal DC Input (Pdco)5,198 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 495 Vdc (NREL SAM Measured)
Max DC Input Voltage495 Vdc
Max DC Input Current14.9 A
Night Tare Loss11.16 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GW5000A-BP
Max Continuous AC Current21 A @ 240V
125% Continuous Duty Current26.3 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.53–6.79 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GW5000A-BP
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for GoodWe GW5000A-BP

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for GoodWe GW5000A-BP
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — GoodWe GW5000A-BP

What size circuit breaker does the GoodWe GW5000A-BP require under NEC 705.12?
At 5.031 kW continuous AC output on 240V (21A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the GoodWe GW5000A-BP?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.031 kW unit with 5.53 kW to 6.79 kW DC of solar modules without exceeding 495V cold Voc.

More GoodWe Inverters

GEC5.0-1U-US20 (4.983 kW)GW5000H-ES (4.989 kW)GEH5.0-1U-US20 (5.005 kW)GW5000A-ES (5.067 kW)GW5000A-MS (5.067 kW)GEH6.0-1U-US20 (5.997 kW)All GoodWe Equipment →