GoodWe official logoCEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

GoodWe GW9600-MS-US30 (9.566 kW)

9.6 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.566 kW
CEC Weighted Eff.
97%
MPPT / Max DC
210–500V / 500V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
GoodWe GW9600-MS-US30 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 210–500 Vdc 210V 500V MAX 500V PV DC INPUT ≤ 500V DC 9.566 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

GoodWe GW9600-MS-US30 Electrical and Grid-Support Specifications
ManufacturerGoodWe
Model Number (MPN)GW9600-MS-US30
Inverter TopologyString Inverter
Continuous AC Power (Paco)9.566 kW (9,566 W)
Nominal DC Input (Pdco)9,894 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window210 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current26 A
Night Tare Loss4.5 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GW9600-MS-US30
Max Continuous AC Current39.9 A @ 240V
125% Continuous Duty Current49.9 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.52–12.91 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GW9600-MS-US30
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–23 panels10.4–12.7 kW DC

Compatible Solar Panels for GoodWe GW9600-MS-US30

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for GoodWe GW9600-MS-US30
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — GoodWe GW9600-MS-US30

What size circuit breaker does the GoodWe GW9600-MS-US30 require under NEC 705.12?
At 9.566 kW continuous AC output on 240V (39.9A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the GoodWe GW9600-MS-US30?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.566 kW unit with 10.52 kW to 12.91 kW DC of solar modules without exceeding 500V cold Voc.

More GoodWe Inverters

GW8600A-MS (8.614 kW)GW8600A-BP (8.68 kW)GEP9.6-1-US30 (9.566 kW)GEH9.6-1U-US20 (9.586 kW)GEC9.6-1U-US20 (9.603 kW)GW9600A-BP (9.616 kW)All GoodWe Equipment →