GoodWe GW9600A-ES (9.628 kW)
9.6 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
9.628 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | GoodWe |
|---|---|
| Model Number (MPN) | GW9600A-ES |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 9.628 kW (9,628 W) |
| Nominal DC Input (Pdco) | 9,954 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 300 – 480 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 480 Vdc |
| Max DC Input Current | 24.9 A |
| Night Tare Loss | 9.4 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 40.1 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 50.1 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (10.59–13 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 26–33 panels | 10.4–13.2 kW DC |
| 440W | 24–30 panels | 10.6–13.2 kW DC |
| 550W | 19–24 panels | 10.4–13.2 kW DC |
Compatible Solar Panels for GoodWe GW9600A-ES
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 8–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 8–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-520MB-AG | 520 W | 48.4 V | 9–9 per string (-10°C) | Verify Pair |
| Mission Solar MSX10-460HN0B {C} | 460 W | 39.3 V | 11–11 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 12–12 per string (-10°C) | Verify Pair |
Engineering FAQ — GoodWe GW9600A-ES
What size circuit breaker does the GoodWe GW9600A-ES require under NEC 705.12?
At 9.628 kW continuous AC output on 240V (40.1A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the GoodWe GW9600A-ES?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.628 kW unit with 10.59 kW to 13 kW DC of solar modules without exceeding 480V cold Voc.