GS CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Green Solutions (Chengdu) H12K-US (11.93 kW)

12 kW, 240 Vac Grid Support Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.93 kW
CEC Weighted Eff.
97%
MPPT / Max DC
230–480V / 480V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Green Solutions (Chengdu) H12K-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 230–480 Vdc 230V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.93 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

Green Solutions (Chengdu) H12K-US Electrical and Grid-Support Specifications
ManufacturerGreen Solutions (Chengdu)
Model Number (MPN)H12K-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.93 kW (11,930 W)
Nominal DC Input (Pdco)12,340 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window230 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current34.3 A
Night Tare Loss14.29 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for H12K-US
Max Continuous AC Current49.7 A @ 240V
125% Continuous Duty Current62.1 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (13.12–16.11 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for H12K-US
Panel ClassRecommended QtyDC Array / Ratio
400W33–40 panels13.2–16.0 kW DC
440W30–37 panels13.2–16.3 kW DC
550W24–29 panels13.2–15.9 kW DC

Compatible Solar Panels for Green Solutions (Chengdu) H12K-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Green Solutions (Chengdu) H12K-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Green Solutions (Chengdu) H12K-US

What size circuit breaker does the Green Solutions (Chengdu) H12K-US require under NEC 705.12?
At 11.93 kW continuous AC output on 240V (49.7A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Green Solutions (Chengdu) H12K-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.93 kW unit with 13.12 kW to 16.11 kW DC of solar modules without exceeding 480V cold Voc.