CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)Estimated MPPT — Verify Manufacturer Datasheet
Gwatt Innovations GLADE RM-450M-X (0.903 kW)
0.903 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.903 kW
CEC Weighted Eff.
95%
MPPT / Max DC
25–55V / 60VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Gwatt Innovations |
|---|---|
| Model Number (MPN) | GLADE RM-450M-X |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.903 kW (903 W) |
| Nominal DC Input (Pdco) | 951 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 95% |
| MPPT Operating Window | 25 – 55 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design |
| Max DC Input Voltage | 60 Vdc |
| Max DC Input Current | 25.8 A |
| Night Tare Loss | 0.9 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3.8 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 4.8 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.99–1.22 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.44× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.49× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.61× DC/AC) |
Engineering FAQ — Gwatt Innovations GLADE RM-450M-X
What size circuit breaker does the Gwatt Innovations GLADE RM-450M-X require under NEC 705.12?
At 0.903 kW continuous AC output on 240V (3.8A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Gwatt Innovations GLADE RM-450M-X?
As a 903W microinverter, it pairs 1:1 with panels rated roughly 948W to 1309W STC.