GI CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)Estimated MPPT — Verify Manufacturer Datasheet

Gwatt Innovations GLADE RM-450M-X (0.903 kW)

0.903 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.903 kW
CEC Weighted Eff.
95%
MPPT / Max DC
25–55V / 60VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Gwatt Innovations GLADE RM-450M-X — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 25–55 Vdc 25V 55V MAX 60V PV DC INPUT ≤ 60V DC 0.903 kW · 95% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Gwatt Innovations GLADE RM-450M-X Electrical and Grid-Support Specifications
ManufacturerGwatt Innovations
Model Number (MPN)GLADE RM-450M-X
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.903 kW (903 W)
Nominal DC Input (Pdco)951 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95%
MPPT Operating Window25 – 55 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design
Max DC Input Voltage60 Vdc
Max DC Input Current25.8 A
Night Tare Loss0.9 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GLADE RM-450M-X
Max Continuous AC Current3.8 A @ 240V
125% Continuous Duty Current4.8 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.99–1.22 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GLADE RM-450M-X
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.44× DC/AC)
440W1 panel1:1 pairing (0.49× DC/AC)
550W1 panel1:1 pairing (0.61× DC/AC)

Engineering FAQ — Gwatt Innovations GLADE RM-450M-X

What size circuit breaker does the Gwatt Innovations GLADE RM-450M-X require under NEC 705.12?
At 0.903 kW continuous AC output on 240V (3.8A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Gwatt Innovations GLADE RM-450M-X?
As a 903W microinverter, it pairs 1:1 with panels rated roughly 948W to 1309W STC.

More Gwatt Innovations Inverters

GLADE RM-900M-X (0.45 kW)All Gwatt Innovations Equipment →