HM CEC-Listed · 240V ResidentialMicroinverter

Hoymiles HM-1000N (0.985 kW)

1.0 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.985 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
32–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HM-1000N — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 32–48 Vdc 32V 48V MAX 48V PV DC INPUT ≤ 48V DC 0.985 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HM-1000N Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HM-1000N
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.985 kW (985 W)
Nominal DC Input (Pdco)1,023 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window32 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current25.6 A
Night Tare Loss0.11 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HM-1000N
Max Continuous AC Current4.1 A @ 240V
125% Continuous Duty Current5.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.08–1.33 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HM-1000N
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.41× DC/AC)
440W1 panel1:1 pairing (0.45× DC/AC)
550W1 panel1:1 pairing (0.56× DC/AC)

Engineering FAQ — Hoymiles HM-1000N

What size circuit breaker does the Hoymiles HM-1000N require under NEC 705.12?
At 0.985 kW continuous AC output on 240V (4.1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HM-1000N?
As a 985W microinverter, it pairs 1:1 with panels rated roughly 1034W to 1428W STC.

More Hoymiles Inverters

MIS-900-2NA (0.83 kW)MIS-1000-2NA (0.965 kW)HMS-1000-2T-NA (0.967 kW)HM-1000 (1.032 kW)HM-1200N (1.213 kW)HM-1500N (1.439 kW)All Hoymiles Equipment →