HM CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Hoymiles MIS-450-1NA (0.421 kW)

410 W, 240 Vac, Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.421 kW
CEC Weighted Eff.
97%
MPPT / Max DC
30–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles MIS-450-1NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 30–48 Vdc 30V 48V MAX 48V PV DC INPUT ≤ 48V DC 0.421 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Hoymiles MIS-450-1NA Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)MIS-450-1NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.421 kW (421 W)
Nominal DC Input (Pdco)433 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window30 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current11.1 A
Night Tare Loss0.03 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIS-450-1NA
Max Continuous AC Current1.8 A @ 240V
125% Continuous Duty Current2.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.46–0.57 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIS-450-1NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.95× DC/AC)
440W1 panel1:1 pairing (1.05× DC/AC)
550W1 panel1:1 pairing (1.31× DC/AC)

Compatible Solar Panels for Hoymiles MIS-450-1NA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hoymiles MIS-450-1NA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.38 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.38 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.37 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.33 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.32 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.13 (1 panel/input)Verify Pair

Engineering FAQ — Hoymiles MIS-450-1NA

What size circuit breaker does the Hoymiles MIS-450-1NA require under NEC 705.12?
At 0.421 kW continuous AC output on 240V (1.8A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles MIS-450-1NA?
As a 421W microinverter, it pairs 1:1 with panels rated roughly 442W to 610W STC.

More Hoymiles Inverters

MIS-400-1NA (0.368 kW)HM-400N (0.383 kW)HMS-450-1A-NA (0.411 kW)HMS-500-1A-NA (0.476 kW)MIS-500-1NA (0.476 kW)HM-600N (0.591 kW)All Hoymiles Equipment →