HYXI Power HYX-M600-S-NA (0.549 kW)
0.548 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.549 kW
CEC Weighted Eff.
96%
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | HYXI Power |
|---|---|
| Model Number (MPN) | HYX-M600-S-NA |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.549 kW (549 W) |
| Nominal DC Input (Pdco) | 572 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 96% |
| MPPT Operating Window | 35 – 50 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 50 Vdc |
| Max DC Input Current | 13.6 A |
| Night Tare Loss | 0.2 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 2.3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 2.9 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.6–0.74 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.73× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.80× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.00× DC/AC) |
Compatible Solar Panels for HYXI Power HYX-M600-S-NA
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | DC/AC 1.06 (1 panel/input) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | DC/AC 1.06 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | DC/AC 1.05 (1 panel/input) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | DC/AC 1.02 (1 panel/input) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | DC/AC 1.01 (1 panel/input) | Verify Pair |
| Trina Solar TSM-565NE19RC | 565 W | 46.3 V | DC/AC 1.03 (1 panel/input) | Verify Pair |
Engineering FAQ — HYXI Power HYX-M600-S-NA
What size circuit breaker does the HYXI Power HYX-M600-S-NA require under NEC 705.12?
At 0.549 kW continuous AC output on 240V (2.3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the HYXI Power HYX-M600-S-NA?
As a 549W microinverter, it pairs 1:1 with panels rated roughly 576W to 796W STC.