JW CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Jiangsu Weiheng Intelligent Technology SHD-11.4kW (11.257 kW)

11.4 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.257 kW
CEC Weighted Eff.
97%
MPPT / Max DC
210–550V / 550V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Jiangsu Weiheng Intelligent Technology SHD-11.4kW — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 210–550 Vdc 210V 550V MAX 550V PV DC INPUT ≤ 550V DC 11.257 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Jiangsu Weiheng Intelligent Technology SHD-11.4kW Electrical and Grid-Support Specifications
ManufacturerJiangsu Weiheng Intelligent Technology
Model Number (MPN)SHD-11.4kW
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.257 kW (11,257 W)
Nominal DC Input (Pdco)11,648 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window210 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current28.4 A
Night Tare Loss10.38 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SHD-11.4kW
Max Continuous AC Current46.9 A @ 240V
125% Continuous Duty Current58.6 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.38–15.2 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SHD-11.4kW
Panel ClassRecommended QtyDC Array / Ratio
400W31–38 panels12.4–15.2 kW DC
440W28–35 panels12.3–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for Jiangsu Weiheng Intelligent Technology SHD-11.4kW

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Jiangsu Weiheng Intelligent Technology SHD-11.4kW
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — Jiangsu Weiheng Intelligent Technology SHD-11.4kW

What size circuit breaker does the Jiangsu Weiheng Intelligent Technology SHD-11.4kW require under NEC 705.12?
At 11.257 kW continuous AC output on 240V (46.9A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Jiangsu Weiheng Intelligent Technology SHD-11.4kW?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.257 kW unit with 12.38 kW to 15.2 kW DC of solar modules without exceeding 550V cold Voc.

More Jiangsu Weiheng Intelligent Technology Inverters

SHD-7.6kW (7.572 kW)SHD-9.6kW (9.66 kW)All Jiangsu Weiheng Intelligent Technology Equipment →