KE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Kowint Energy (Shenzhen) KSL-16KU-A (16.131 kW)

16 kW, 240Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
16.131 kW
CEC Weighted Eff.
96%
MPPT / Max DC
220–430V / 430V
NEC 705.12 Breaker
90A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Kowint Energy (Shenzhen) KSL-16KU-A — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 220–430 Vdc 220V 430V MAX 430V PV DC INPUT ≤ 430V DC 16.131 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 90A BRKR

Electrical & Grid-Support Datasheet

Kowint Energy (Shenzhen) KSL-16KU-A Electrical and Grid-Support Specifications
ManufacturerKowint Energy (Shenzhen)
Model Number (MPN)KSL-16KU-A
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)16.131 kW (16,131 W)
Nominal DC Input (Pdco)16,782 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window220 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current46.6 A
Night Tare Loss19.23 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for KSL-16KU-A
Max Continuous AC Current67.2 A @ 240V
125% Continuous Duty Current84.0 A
Minimum Standard Breaker90 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (17.74–21.78 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for KSL-16KU-A
Panel ClassRecommended QtyDC Array / Ratio
400W44–54 panels17.6–21.6 kW DC
440W40–50 panels17.6–22.0 kW DC
550W32–40 panels17.6–22.0 kW DC

Compatible Solar Panels for Kowint Energy (Shenzhen) KSL-16KU-A

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Kowint Energy (Shenzhen) KSL-16KU-A
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Kowint Energy (Shenzhen) KSL-16KU-A

What size circuit breaker does the Kowint Energy (Shenzhen) KSL-16KU-A require under NEC 705.12?
At 16.131 kW continuous AC output on 240V (67.2A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Kowint Energy (Shenzhen) KSL-16KU-A?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 16.131 kW unit with 17.74 kW to 21.78 kW DC of solar modules without exceeding 430V cold Voc.

More Kowint Energy (Shenzhen) Inverters

KSL-8KU-B (8.181 kW)KSL-12KU-A (12.137 kW)KSL-12KU-B (12.214 kW)KSL-16KU-B (16.199 kW)KSL-8KU-A (8.111 kW)All Kowint Energy (Shenzhen) Equipment →