LE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Liniotech Energy LNT10K0228UL (10.147 kW)

10 kW, 240 Vac Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
10.147 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Liniotech Energy LNT10K0228UL — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 10.147 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Liniotech Energy LNT10K0228UL Electrical and Grid-Support Specifications
ManufacturerLiniotech Energy
Model Number (MPN)LNT10K0228UL
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)10.147 kW (10,147 W)
Nominal DC Input (Pdco)10,509 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current29.2 A
Night Tare Loss18 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for LNT10K0228UL
Max Continuous AC Current42.3 A @ 240V
125% Continuous Duty Current52.9 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (11.16–13.7 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for LNT10K0228UL
Panel ClassRecommended QtyDC Array / Ratio
400W28–34 panels11.2–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Liniotech Energy LNT10K0228UL

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Liniotech Energy LNT10K0228UL
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Liniotech Energy LNT10K0228UL

What size circuit breaker does the Liniotech Energy LNT10K0228UL require under NEC 705.12?
At 10.147 kW continuous AC output on 240V (42.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Liniotech Energy LNT10K0228UL?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10.147 kW unit with 11.16 kW to 13.7 kW DC of solar modules without exceeding 480V cold Voc.

More Liniotech Energy Inverters

LNT7K0228UL (7.647 kW)LNT8K0228UL (8.047 kW)LNT12K0228UL (10.14 kW)LNT5K0228UL (5.04 kW)LNT6K0228UL (6.149 kW)All Liniotech Energy Equipment →