LO CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Lite-On Technology IN-HP5123US (9.019 kW)

10 kW, 240 Vac, Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.019 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
285–500V / 500V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Lite-On Technology IN-HP5123US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 285–500 Vdc 285V 500V MAX 500V PV DC INPUT ≤ 500V DC 9.019 kW · 95.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

Lite-On Technology IN-HP5123US Electrical and Grid-Support Specifications
ManufacturerLite-On Technology
Model Number (MPN)IN-HP5123US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.019 kW (9,019 W)
Nominal DC Input (Pdco)9,409 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants120V, 240V
CEC Weighted Efficiency95.5%
MPPT Operating Window285 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current26.1 A
Night Tare Loss4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IN-HP5123US
Max Continuous AC Current37.6 A @ 240V
125% Continuous Duty Current47.0 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (9.92–12.18 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IN-HP5123US
Panel ClassRecommended QtyDC Array / Ratio
400W25–30 panels10.0–12.0 kW DC
440W23–28 panels10.1–12.3 kW DC
550W18–22 panels9.9–12.1 kW DC

Compatible Solar Panels for Lite-On Technology IN-HP5123US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Lite-On Technology IN-HP5123US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — Lite-On Technology IN-HP5123US

What size circuit breaker does the Lite-On Technology IN-HP5123US require under NEC 705.12?
At 9.019 kW continuous AC output on 240V (37.6A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Lite-On Technology IN-HP5123US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.019 kW unit with 9.92 kW to 12.18 kW DC of solar modules without exceeding 500V cold Voc.

More Lite-On Technology Inverters

IN-HP5113US (11.361 kW)All Lite-On Technology Equipment →