Lunar Energy 10-005025 (9.675 kW)
9.6 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
9.675 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
380–450V / 450V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Lunar Energy |
|---|---|
| Model Number (MPN) | 10-005025 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 9.675 kW (9,675 W) |
| Nominal DC Input (Pdco) | 10,063 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 95.5% |
| MPPT Operating Window | 380 – 450 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 450 Vdc |
| Max DC Input Current | 24.2 A |
| Night Tare Loss | 29.61 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 40.3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 50.4 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (10.64–13.06 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 27–33 panels | 10.8–13.2 kW DC |
| 440W | 24–30 panels | 10.6–13.2 kW DC |
| 550W | 19–24 panels | 10.4–13.2 kW DC |
Engineering FAQ — Lunar Energy 10-005025
What size circuit breaker does the Lunar Energy 10-005025 require under NEC 705.12?
At 9.675 kW continuous AC output on 240V (40.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Lunar Energy 10-005025?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.675 kW unit with 10.64 kW to 13.06 kW DC of solar modules without exceeding 450V cold Voc.