LE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Lunar Energy 10-005025 (9.675 kW)

9.6 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive PV and Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.675 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
380–450V / 450V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Lunar Energy 10-005025 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 380–450 Vdc 380V 450V MAX 450V PV DC INPUT ≤ 450V DC 9.675 kW · 95.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Lunar Energy 10-005025 Electrical and Grid-Support Specifications
ManufacturerLunar Energy
Model Number (MPN)10-005025
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.675 kW (9,675 W)
Nominal DC Input (Pdco)10,063 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95.5%
MPPT Operating Window380 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current24.2 A
Night Tare Loss29.61 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 10-005025
Max Continuous AC Current40.3 A @ 240V
125% Continuous Duty Current50.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.64–13.06 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 10-005025
Panel ClassRecommended QtyDC Array / Ratio
400W27–33 panels10.8–13.2 kW DC
440W24–30 panels10.6–13.2 kW DC
550W19–24 panels10.4–13.2 kW DC

Engineering FAQ — Lunar Energy 10-005025

What size circuit breaker does the Lunar Energy 10-005025 require under NEC 705.12?
At 9.675 kW continuous AC output on 240V (40.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Lunar Energy 10-005025?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.675 kW unit with 10.64 kW to 13.06 kW DC of solar modules without exceeding 450V cold Voc.