MS CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

MPP SOLAR LVX 12KW WP (9.019 kW)

10 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.019 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
285–500V / 500V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
MPP SOLAR LVX 12KW WP — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 285–500 Vdc 285V 500V MAX 500V PV DC INPUT ≤ 500V DC 9.019 kW · 95.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

MPP SOLAR LVX 12KW WP Electrical and Grid-Support Specifications
ManufacturerMPP SOLAR
Model Number (MPN)LVX 12KW WP
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.019 kW (9,019 W)
Nominal DC Input (Pdco)9,412 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants120V, 240V
CEC Weighted Efficiency95.5%
MPPT Operating Window285 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current26.1 A
Night Tare Loss4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for LVX 12KW WP
Max Continuous AC Current37.6 A @ 240V
125% Continuous Duty Current47.0 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (9.92–12.18 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for LVX 12KW WP
Panel ClassRecommended QtyDC Array / Ratio
400W25–30 panels10.0–12.0 kW DC
440W23–28 panels10.1–12.3 kW DC
550W18–22 panels9.9–12.1 kW DC

Compatible Solar Panels for MPP SOLAR LVX 12KW WP

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for MPP SOLAR LVX 12KW WP
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — MPP SOLAR LVX 12KW WP

What size circuit breaker does the MPP SOLAR LVX 12KW WP require under NEC 705.12?
At 9.019 kW continuous AC output on 240V (37.6A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the MPP SOLAR LVX 12KW WP?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.019 kW unit with 9.92 kW to 12.18 kW DC of solar modules without exceeding 500V cold Voc.