OI CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Oxford Intelligent Energy OE 8KHS/LV (8.047 kW)

8 kW, 240 Vac, Grid Support Utility Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.047 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–480V / 480V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Oxford Intelligent Energy OE 8KHS/LV — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–480 Vdc 200V 480V MAX 480V PV DC INPUT ≤ 480V DC 8.047 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Oxford Intelligent Energy OE 8KHS/LV Electrical and Grid-Support Specifications
ManufacturerOxford Intelligent Energy
Model Number (MPN)OE 8KHS/LV
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.047 kW (8,047 W)
Nominal DC Input (Pdco)8,335 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current23.2 A
Night Tare Loss15 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for OE 8KHS/LV
Max Continuous AC Current33.5 A @ 240V
125% Continuous Duty Current41.9 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.85–10.86 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for OE 8KHS/LV
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for Oxford Intelligent Energy OE 8KHS/LV

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Oxford Intelligent Energy OE 8KHS/LV
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Oxford Intelligent Energy OE 8KHS/LV

What size circuit breaker does the Oxford Intelligent Energy OE 8KHS/LV require under NEC 705.12?
At 8.047 kW continuous AC output on 240V (33.5A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Oxford Intelligent Energy OE 8KHS/LV?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.047 kW unit with 8.85 kW to 10.86 kW DC of solar modules without exceeding 480V cold Voc.

More Oxford Intelligent Energy Inverters

OE 5KHS/LV (5.04 kW)OE 6KHS/LV (6.149 kW)OE 7K6HS/LV (7.647 kW)OE 11K4HS/LV (10.14 kW)OE 10KHS/LV (10.147 kW)All Oxford Intelligent Energy Equipment →