Panasonic official logoLegacy / Replacement ReferenceHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Panasonic EVHB-I7 (7.608 kW)

7.6 kW, 240 Vac Grid support utility-interactive Power Conversion System. Capable of PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.608 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
234–498V / 498V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Legacy / Replacement Reference: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Panasonic EVHB-I7 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 234–498 Vdc 234V 498V MAX 498V PV DC INPUT ≤ 498V DC 7.608 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Panasonic EVHB-I7 Electrical and Grid-Support Specifications
ManufacturerPanasonic
Model Number (MPN)EVHB-I7
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.608 kW (7,608 W)
Nominal DC Input (Pdco)7,822 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window234 – 498 Vdc (NREL SAM Measured)
Max DC Input Voltage498 Vdc
Max DC Input Current21.4 A
Night Tare Loss7.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for EVHB-I7
Max Continuous AC Current31.7 A @ 240V
125% Continuous Duty Current39.6 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.37–10.27 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for EVHB-I7
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Panasonic EVHB-I7

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Panasonic EVHB-I7
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–7 per string (-10°C)Verify Pair

Engineering FAQ — Panasonic EVHB-I7

What size circuit breaker does the Panasonic EVHB-I7 require under NEC 705.12?
At 7.608 kW continuous AC output on 240V (31.7A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Panasonic EVHB-I7?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.608 kW unit with 8.37 kW to 10.27 kW DC of solar modules without exceeding 498V cold Voc.